pg_stat_statements
|
userid oid |
dbid oid |
toplevel boolean |
queryid bigint |
query text |
plans bigint |
total_plan_time double precision |
min_plan_time double precision |
max_plan_time double precision |
mean_plan_time double precision |
stddev_plan_time double precision |
calls bigint |
total_exec_time double precision |
min_exec_time double precision |
max_exec_time double precision |
mean_exec_time double precision |
stddev_exec_time double precision |
rows bigint |
shared_blks_hit bigint |
shared_blks_read bigint |
shared_blks_dirtied bigint |
shared_blks_written bigint |
local_blks_hit bigint |
local_blks_read bigint |
local_blks_dirtied bigint |
local_blks_written bigint |
temp_blks_read bigint |
temp_blks_written bigint |
blk_read_time double precision |
blk_write_time double precision |
wal_records bigint |
wal_fpi bigint |
wal_bytes numeric |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 16385 | 16384 | t | 7949981054851130074 | INSERT INTO "tbl001EC60537E0_3" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 1930 | 110.06885599999985 | 0.020604 | 1.8015489999999998 | 0.057030495336787584 | 0.10227963898161015 | 1930 | 11641 | 37 | 3363 | 39 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 5796 | 3797 | 16379223 |
| 16385 | 16384 | t | 65544975340227788 | INSERT INTO "tbl001EC6050BAC_7" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 9584 | 542.8680059999997 | 0.016606 | 80.97954899999999 | 0.05664315588480794 | 0.8702239664141838 | 9584 | 58265 | 101 | 5298 | 161 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 28779 | 5090 | 23329408 |
| 16385 | 16384 | t | 1814370596331611952 | INSERT INTO "tbl001EC6053CD9_10" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 2854 | 147.47709500000016 | 0.017978 | 1.937707 | 0.05167382445690259 | 0.0777100924375875 | 2854 | 17271 | 24 | 3759 | 92 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8570 | 3626 | 15762904 |
| 16385 | 16384 | t | 6305699317791867522 | COPY public."tbl001EC6050F3C_33" ("time", error, lowrange, highrange, "Vln_a_Volts_1", "Vln_b_Volts_2", "Vln_c_Volts_3", "Vln_ave_Volts_4", "Vll_ab_Volts_5", "Vll_bc_Volts_6", "Vll_ca_Volts_7", "Vll_ave_Volts_8", "I_a_Amps_9", "I_b_Amps_10", "I_c_Amps_11", "I_ave_Amps_12", "V_unbal_13", "I_unbal_14", "Freq_Hz_15", "I4_Amps_16", "kW_a_kW_17", "kW_b_kW_18", "kW_c_kW_19", "kW_tot_kW_20", "kVAR_a_kVAR_21", "kVAR_b_kVAR_22", "kVAR_c_kVAR_23", "kVAR_tot_kVAR_24", "kVA_a_kVA_25", "kVA_b_kVA_26", "kVA_c_kVA_27", "kVA_tot_kVA_28", "PF_sign_a_29", "PF_sign_b_30", "PF_sign_c_31", "PF_sign_tot_32", "Vll_ave_mx_Volts_33", "I_ave_mx_Amps_34", "kW_tot_mx_kW_35", "kVAR_tot_mx_kVAR_36", "kVA_tot_mx_kVA_37", "Freq_mx_Hz_38", "Vll_ave_mn_Volts_39", "I_ave_mn_Amps_40", "Freq_mn_Hz_41", "kW_sd_del_rec_kW_42", "kVA_sd_del_rec_kVA_43", "kVAR_sd_del_rec_kVAR_44", "kW_sd_mx_d_r_kW_45", "kVA_sd_mx_d_r_kVA_46", "kVAR_sd_mx_d_r_kVAR_47", "Phase_Rev_48", "kWh_del_kWh_49", "kWh_rec_kWh_50", "kWh_del_rec_kWh_51", "kWh_del_rec_kWh_52", "kVARh_del_kVARh_53", "kVARh_rec_kVARh_54", "kVARh_del_rec_kVARh_55", "kVARh_del_rec_kVARh_56", "kVAh_del_rec_kVAh_57", "V1_THD_mx_58", "V2_THD_mx_59", "V3_THD_mx_60", "I1_THD_mx_61", "I2_THD_mx_62", "I3_THD_mx_63", unused_64) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.117183 | 0.117183 | 0.117183 | 0.117183 | 0 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 8965768295221661438 | SELECT * FROM "tbl001EC6053093_9" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29206 | 914.7796719999963 | 0.018372999999999997 | 4.861432 | 0.03132163500650544 | 0.06571592877409639 | 29206 | 116790 | 34 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5933109379755905979 | CREATE TABLE IF NOT EXISTS "tbl001EC60537E0_41" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Analog_In_1_1" DOUBLE PRECISION DEFAULT NULL, "Analog_In_2_2" DOUBLE PRECISION DEFAULT NULL, "Analog_In_3_3" DOUBLE PRECISION DEFAULT NULL, "Analog_In_4_4" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_5" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_6" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_7" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_8" DOUBLE PRECISION DEFAULT NULL, "Status_register_9" DOUBLE PRECISION DEFAULT NULL, "firmware_version_10" DOUBLE PRECISION DEFAULT NULL, "Uptime_Seconds_11" DOUBLE PRECISION DEFAULT NULL, "Pulse_State_Register_12" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_ontime_Sec_sec_13" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_ontime_Sec_sec_14" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_ontime_Sec_sec_15" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_ontime_Sec_sec_16" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_last_minute_change_17" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_last_minute_change_18" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_last_minute_change_19" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_last_minute_change_20" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 5.317812 | 5.317812 | 5.317812 | 5.317812 | 0 | 0 | 574 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 145 | 2 | 16904 |
| 16385 | 16384 | t | 3201703779189533466 | CREATE TABLE IF NOT EXISTS "tbl001EC6050F42_2" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Vln_a_Volts_1" DOUBLE PRECISION DEFAULT NULL, "Vln_b_Volts_2" DOUBLE PRECISION DEFAULT NULL, "Vln_c_Volts_3" DOUBLE PRECISION DEFAULT NULL, "Vln_ave_Volts_4" DOUBLE PRECISION DEFAULT NULL, "Vll_ab_Volts_5" DOUBLE PRECISION DEFAULT NULL, "Vll_bc_Volts_6" DOUBLE PRECISION DEFAULT NULL, "Vll_ca_Volts_7" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_Volts_8" DOUBLE PRECISION DEFAULT NULL, "I_a_Amps_9" DOUBLE PRECISION DEFAULT NULL, "I_b_Amps_10" DOUBLE PRECISION DEFAULT NULL, "I_c_Amps_11" DOUBLE PRECISION DEFAULT NULL, "I_ave_Amps_12" DOUBLE PRECISION DEFAULT NULL, "V_unbal_13" DOUBLE PRECISION DEFAULT NULL, "I_unbal_14" DOUBLE PRECISION DEFAULT NULL, "Freq_Hz_15" DOUBLE PRECISION DEFAULT NULL, "I4_Amps_16" DOUBLE PRECISION DEFAULT NULL, "kW_a_kW_17" DOUBLE PRECISION DEFAULT NULL, "kW_b_kW_18" DOUBLE PRECISION DEFAULT NULL, "kW_c_kW_19" DOUBLE PRECISION DEFAULT NULL, "kW_tot_kW_20" DOUBLE PRECISION DEFAULT NULL, "kVAR_a_kVAR_21" DOUBLE PRECISION DEFAULT NULL, "kVAR_b_kVAR_22" DOUBLE PRECISION DEFAULT NULL, "kVAR_c_kVAR_23" DOUBLE PRECISION DEFAULT NULL, "kVAR_tot_kVAR_24" DOUBLE PRECISION DEFAULT NULL, "kVA_a_kVA_25" DOUBLE PRECISION DEFAULT NULL, "kVA_b_kVA_26" DOUBLE PRECISION DEFAULT NULL, "kVA_c_kVA_27" DOUBLE PRECISION DEFAULT NULL, "kVA_tot_kVA_28" DOUBLE PRECISION DEFAULT NULL, "PF_sign_a_29" DOUBLE PRECISION DEFAULT NULL, "PF_sign_b_30" DOUBLE PRECISION DEFAULT NULL, "PF_sign_c_31" DOUBLE PRECISION DEFAULT NULL, "PF_sign_tot_32" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_mx_Volts_33" DOUBLE PRECISION DEFAULT NULL, "I_ave_mx_Amps_34" DOUBLE PRECISION DEFAULT NULL, "kW_tot_mx_kW_35" DOUBLE PRECISION DEFAULT NULL, "kVAR_tot_mx_kVAR_36" DOUBLE PRECISION DEFAULT NULL, "kVA_tot_mx_kVA_37" DOUBLE PRECISION DEFAULT NULL, "Freq_mx_Hz_38" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_mn_Volts_39" DOUBLE PRECISION DEFAULT NULL, "I_ave_mn_Amps_40" DOUBLE PRECISION DEFAULT NULL, "Freq_mn_Hz_41" DOUBLE PRECISION DEFAULT NULL, "kW_sd_del_rec_kW_42" DOUBLE PRECISION DEFAULT NULL, "kVA_sd_del_rec_kVA_43" DOUBLE PRECISION DEFAULT NULL, "kVAR_sd_del_rec_kVAR_44" DOUBLE PRECISION DEFAULT NULL, "kW_sd_mx_d_r_kW_45" DOUBLE PRECISION DEFAULT NULL, "kVA_sd_mx_d_r_kVA_46" DOUBLE PRECISION DEFAULT NULL, "kVAR_sd_mx_d_r_kVAR_47" DOUBLE PRECISION DEFAULT NULL, "Phase_Rev_48" DOUBLE PRECISION DEFAULT NULL, "kWh_del_kWh_49" DOUBLE PRECISION DEFAULT NULL, "kWh_rec_kWh_50" DOUBLE PRECISION DEFAULT NULL, "kWh_del_rec_kWh_51" DOUBLE PRECISION DEFAULT NULL, "kWh_del_rec_kWh_52" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_kVARh_53" DOUBLE PRECISION DEFAULT NULL, "kVARh_rec_kVARh_54" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_rec_kVARh_55" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_rec_kVARh_56" DOUBLE PRECISION DEFAULT NULL, "kVAh_del_rec_kVAh_57" DOUBLE PRECISION DEFAULT NULL, "V1_THD_mx_58" DOUBLE PRECISION DEFAULT NULL, "V2_THD_mx_59" DOUBLE PRECISION DEFAULT NULL, "V3_THD_mx_60" DOUBLE PRECISION DEFAULT NULL, "I1_THD_mx_61" DOUBLE PRECISION DEFAULT NULL, "I2_THD_mx_62" DOUBLE PRECISION DEFAULT NULL, "I3_THD_mx_63" DOUBLE PRECISION DEFAULT NULL, "unused_64" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.206942 | 6.206942 | 6.206942 | 6.206942 | 0 | 0 | 977 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 242 | 2 | 30091 |
| 16385 | 16384 | t | 6030022282230177435 | INSERT INTO "tbl001EC6050F3C_12" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 67 | 3.411276 | 0.028471 | 0.185651 | 0.050914567164179095 | 0.023840056878014812 | 67 | 269 | 0 | 133 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 202 | 130 | 196715 |
| 16385 | 16384 | t | 2897522876661520132 | LOCK TABLE public."tbl001EC6050F3C_14" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.022681 | 0.022681 | 0.022681 | 0.022681 | 0 | 0 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1022216283660081612 | SELECT * FROM "tbl001EC6053113_9" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 28608 | 1310.7948470000053 | 0.028767 | 5.733714 | 0.04581917110598411 | 0.04780128646960489 | 28608 | 85806 | 18 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4559525109671902606 | SELECT * FROM "tbl001EC60537E0_1" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 3860 | 96.66497100000016 | 0.005742000000000001 | 3.162187 | 0.025042738601036327 | 0.06564048964542779 | 3859 | 10765 | 3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3494879671813421537 | INSERT INTO "tbl001EC6050BAC_3" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 9584 | 524.886274000001 | 0.015511 | 67.687707 | 0.05476693176126875 | 0.7121096551277554 | 9584 | 58171 | 87 | 5140 | 171 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 28779 | 4904 | 22784678 |
| 16385 | 16384 | t | -8515388520039940802 | SELECT * FROM "tbl001EC6050F3A_51" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 8 | 12.483458 | 0.468707 | 4.438079999999999 | 1.56043225 | 1.5003230523252107 | 800 | 68 | 11 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2143533060631656847 | SELECT * FROM "tbl001EC6050D05_51" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29210 | 938.731512999997 | 0.018909000000000002 | 4.428598 | 0.03213733355015398 | 0.044444038298325605 | 29210 | 116831 | 9 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1279096003048624513 | COPY public."tbl001EC60537E0_3" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 35.916669999999996 | 0.06737 | 15.747395 | 5.130952857142857 | 4.892910191511633 | 6195 | 51 | 65 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5467053905531392763 | COPY public."tbl001EC6053CD9_4" ("time", error, lowrange, highrange, "Energy_Consumption_kWh_1", "Real_Power_kW_2") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 31.776856 | 0.114701 | 12.909934 | 5.296142666666666 | 4.2816612545692925 | 8118 | 55 | 45 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7815281640518297196 | LOCK TABLE public."tbl001EC6056D48_51" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.36109 | 0.01945 | 0.090417 | 0.036109 | 0.02313253820487497 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7251826586634779737 | LOCK TABLE public."tbl001EC605309C_53" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.29294800000000004 | 0.019017 | 0.086496 | 0.029294800000000003 | 0.019485724681417422 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3389129273360096534 | LOCK TABLE public.dl_meter_device_data IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.4968970000000001 | 0.020181 | 0.179416 | 0.0496897 | 0.04704280804129363 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6672424749522332880 | COPY public.tbldevicelist (serialnumber, deviceid, devicename, devicetype, deviceclass, config, configchangetime, configchecksum, datatablename) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 210.91353900000001 | 12.804661 | 35.629988 | 21.0913539 | 6.700911687457885 | 1701 | 1889 | 124 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6802550087586260544 | SELECT * FROM "tbl001EC6050189_33" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1674 | 90.92310900000017 | 0.021772 | 1.987768 | 0.054314879928315296 | 0.0982610202756649 | 1673 | 4193 | 19 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | -9030696468456313006 | CREATE TABLE _276d05969ee20125dee39571315bf6a1(cmd_output text) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 10.504071 | 10.504071 | 10.504071 | 10.504071 | 0 | 0 | 501 | 5 | 24 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 92 | 25 | 122929 |
| 16385 | 16384 | t | 7451525619227643169 | SELECT * FROM "tbl001EC6050BAC_7" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 0.759827 | 0.08570499999999999 | 0.125105 | 0.10854671428571427 | 0.014184532438180542 | 700 | 108 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7285949714286782777 | LOCK TABLE public."tbl001EC6056300_53" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.381376 | 0.021251 | 0.061555 | 0.038137599999999994 | 0.012056469435120714 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7656608426194004174 | SELECT * FROM "tbl001EC6053CD9_5" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 5 | 0.656455 | 0.117203 | 0.16325800000000001 | 0.13129100000000002 | 0.01688141573446967 | 500 | 375 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3118720287759231126 | INSERT INTO "tbl001EC6050D16_50" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 71394 | 2121.078010000021 | 0.013601 | 80.504194 | 0.02970947152421743 | 0.32152266033583315 | 71394 | 432256 | 27 | 3467 | 2140 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 214379 | 1300 | 31512960 |
| 16385 | 16384 | t | 3686759338601217105 | SELECT * FROM "tbl001EC6050D16_51" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1922 | 52.24334600000003 | 0.005687 | 2.269833 | 0.027181761706555688 | 0.0815021346971344 | 1921 | 5757 | 7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7006951292212829354 | COPY public."tbl001EC6056300_50" ("time", error, lowrange, highrange, "VAB_V_1", "VBC_V_2", "VCA_V_3", "Current_A_A_4", "Current_B_A_5", "Current_C_A_6", "Real_Power_kW_7", "PV_Voltage_V_8", "PV_Current_A_9", "PV_Power_kW_10", "Grid_Frequency_Hz_11", "System_State_12", "Goal_State_13", "Fault_Code_14", "Accumulated_Energy_kWh_15", "R_Matrix_Temp_Degrees_C_16", "L_Matrix_Temp_Degrees_C_17", "Intake_Air_Temperature_Degrees_C_18") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 13896.184371000001 | 1097.062547 | 1728.1266150000001 | 1389.6184371 | 172.19518415382174 | 2140590 | 274 | 69296 | 14 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 485016310711430062 | SELECT * FROM "tbl001EC6050F3C_3" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 134 | 5.315760999999998 | 0.010042 | 1.339273 | 0.0396698582089552 | 0.11347552782955589 | 133 | 265 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | 509043065338986260 | CREATE TABLE _ab6d56c31864922703c761538e38f2b8(cmd_output text) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.200314 | 6.200314 | 6.200314 | 6.200314 | 0 | 0 | 504 | 2 | 3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 92 | 4 | 23185 |
| 16385 | 16384 | t | 7406351295613100700 | COPY public."tbl001EC6054E88_103" ("time", error, lowrange, highrange, "Vln_a_Volts_1", "Vln_b_Volts_2", "Vln_c_Volts_3", "Vln_ave_Volts_4", "Vll_ab_Volts_5", "Vll_bc_Volts_6", "Vll_ca_Volts_7", "Vll_ave_Volts_8", "I_a_Amps_9", "I_b_Amps_10", "I_c_Amps_11", "I_ave_Amps_12", "V_unbal_13", "I_unbal_14", "Freq_Hz_15", "I4_Amps_16", "kW_a_kW_17", "kW_b_kW_18", "kW_c_kW_19", "kW_tot_kW_20", "kVAR_a_kVAR_21", "kVAR_b_kVAR_22", "kVAR_c_kVAR_23", "kVAR_tot_kVAR_24", "kVA_a_kVA_25", "kVA_b_kVA_26", "kVA_c_kVA_27", "kVA_tot_kVA_28", "PF_sign_a_29", "PF_sign_b_30", "PF_sign_c_31", "PF_sign_tot_32", "Vll_ave_mx_Volts_33", "I_ave_mx_Amps_34", "kW_tot_mx_kW_35", "kVAR_tot_mx_kVAR_36", "kVA_tot_mx_kVA_37", "Freq_mx_Hz_38", "Vll_ave_mn_Volts_39", "I_ave_mn_Amps_40", "Freq_mn_Hz_41", "kW_sd_del_rec_kW_42", "kVA_sd_del_rec_kVA_43", "kVAR_sd_del_rec_kVAR_44", "kW_sd_mx_d_r_kW_45", "kVA_sd_mx_d_r_kVA_46", "kVAR_sd_mx_d_r_kVAR_47", "Phase_Rev_48", "kWh_del_kWh_49", "kWh_rec_kWh_50", "kWh_del_rec_kWh_51", "kWh_del_rec_kWh_52", "kVARh_del_kVARh_53", "kVARh_rec_kVARh_54", "kVARh_del_rec_kVARh_55", "kVARh_del_rec_kVARh_56", "kVAh_del_rec_kVAh_57", "V1_THD_mx_58", "V2_THD_mx_59", "V3_THD_mx_60", "I1_THD_mx_61", "I2_THD_mx_62", "I3_THD_mx_63", unused_64) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 904.4322119999999 | 264.967587 | 348.604364 | 301.477404 | 34.96017172773201 | 52764 | 1298 | 2509 | 44 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3429958618568471424 | CREATE TABLE IF NOT EXISTS "tbl001EC6053109_2" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "AC_Current_Amps_1" DOUBLE PRECISION DEFAULT NULL, "Phase_A_Current_Amps_2" DOUBLE PRECISION DEFAULT NULL, "Phase_B_Current_Amps_3" DOUBLE PRECISION DEFAULT NULL, "Phase_C_Current_Amps_4" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_AB_Volts_5" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_BC_Volts_6" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_CA_Volts_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_AN_Volts_8" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_BN_Volts_9" DOUBLE PRECISION DEFAULT NULL, "Phase_Voltage_CN_Volts_10" DOUBLE PRECISION DEFAULT NULL, "AC_Power_W_11" DOUBLE PRECISION DEFAULT NULL, "Line_Frequency_Hz_12" DOUBLE PRECISION DEFAULT NULL, "AC_Apparent_Power_VA_13" DOUBLE PRECISION DEFAULT NULL, "AC_Reactive_Power_VAR_14" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Factor_15" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_Wh_16" DOUBLE PRECISION DEFAULT NULL, "DC_Amps_Amps_17" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_Volts_18" DOUBLE PRECISION DEFAULT NULL, "DC_Power_W_19" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_Degrees_20" DOUBLE PRECISION DEFAULT NULL, "Heat_Sink_Temperature_Degrees_21" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_Degrees_22" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_Degrees_23" DOUBLE PRECISION DEFAULT NULL, "Operating_State_24" DOUBLE PRECISION DEFAULT NULL, "Vendor_Specific_Operating_State_25" DOUBLE PRECISION DEFAULT NULL, "Event_Field_26" DOUBLE PRECISION DEFAULT NULL, "Reserved_for_Future_27" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_1_28" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_2_29" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_3_30" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_4_31" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 11.72393 | 11.72393 | 11.72393 | 11.72393 | 0 | 0 | 873 | 5 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 163 | 36 | 178339 |
| 16385 | 16384 | t | 6423695676518781385 | COPY public."tbl001EC6050D05_103" ("time", error, lowrange, highrange, "Vln_a_Volts_1", "Vln_b_Volts_2", "Vln_c_Volts_3", "Vln_ave_Volts_4", "Vll_ab_Volts_5", "Vll_bc_Volts_6", "Vll_ca_Volts_7", "Vll_ave_Volts_8", "I_a_Amps_9", "I_b_Amps_10", "I_c_Amps_11", "I_ave_Amps_12", "V_unbal_13", "I_unbal_14", "Freq_Hz_15", "I4_Amps_16", "kW_a_kW_17", "kW_b_kW_18", "kW_c_kW_19", "kW_tot_kW_20", "kVAR_a_kVAR_21", "kVAR_b_kVAR_22", "kVAR_c_kVAR_23", "kVAR_tot_kVAR_24", "kVA_a_kVA_25", "kVA_b_kVA_26", "kVA_c_kVA_27", "kVA_tot_kVA_28", "PF_sign_a_29", "PF_sign_b_30", "PF_sign_c_31", "PF_sign_tot_32", "Vll_ave_mx_Volts_33", "I_ave_mx_Amps_34", "kW_tot_mx_kW_35", "kVAR_tot_mx_kVAR_36", "kVA_tot_mx_kVA_37", "Freq_mx_Hz_38", "Vll_ave_mn_Volts_39", "I_ave_mn_Amps_40", "Freq_mn_Hz_41", "kW_sd_del_rec_kW_42", "kVA_sd_del_rec_kVA_43", "kVAR_sd_del_rec_kVAR_44", "kW_sd_mx_d_r_kW_45", "kVA_sd_mx_d_r_kVA_46", "kVAR_sd_mx_d_r_kVAR_47", "Phase_Rev_48", "kWh_del_kWh_49", "kWh_rec_kWh_50", "kWh_del_rec_kWh_51", "kWh_del_rec_kWh_52", "kVARh_del_kVARh_53", "kVARh_rec_kVARh_54", "kVARh_del_rec_kVARh_55", "kVARh_del_rec_kVARh_56", "kVAh_del_rec_kVAh_57", "V1_THD_mx_58", "V2_THD_mx_59", "V3_THD_mx_60", "I1_THD_mx_61", "I2_THD_mx_62", "I3_THD_mx_63", unused_64) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 35225.693124 | 3321.122602 | 3677.338995 | 3522.5693124 | 114.91457105475004 | 2038740 | 1667 | 159516 | 50 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1391901306320756083 | COPY public."tbl001EC6053093_54" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 29351.903581 | 2674.736839 | 3372.074544 | 2935.1903580999997 | 197.93990083133895 | 2124140 | 11572 | 194766 | 49 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8299171435924775676 | INSERT INTO "tbl001EC6050F42_1" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 73 | 3.976727999999999 | 0.012946 | 0.9209700000000001 | 0.05447572602739725 | 0.1032041822019812 | 72 | 291 | 0 | 143 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 217 | 140 | 395806 |
| 16385 | 16384 | t | -8693187967704674284 | INSERT INTO "tbl001EC6053075_7" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 793 | 38.36849100000002 | 0.024131 | 0.940908 | 0.048383973518285064 | 0.060853184333102 | 793 | 4120 | 6 | 1253 | 12 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2382 | 1532 | 6483199 |
| 16385 | 16384 | t | -4910450954336119731 | LOCK TABLE public."tbl001EC6050F3C_17" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.027899 | 0.027899 | 0.027899 | 0.027899 | 0 | 0 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -479604193929285912 | CREATE TABLE IF NOT EXISTS "tbl001EC6050B5D_1" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "DC_Voltage_V_1" DOUBLE PRECISION DEFAULT NULL, "Apparent_AC_Power_VA_2" DOUBLE PRECISION DEFAULT NULL, "AC_Grid_Frequency_Hz_3" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Stage_Current_A_4" DOUBLE PRECISION DEFAULT NULL, "L1_to_L2_AC_Voltage_V_5" DOUBLE PRECISION DEFAULT NULL, "L2_to_L3_AC_Voltage_V_6" DOUBLE PRECISION DEFAULT NULL, "L1_to_L3_AC_Voltage_V_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Sequence_8" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_kWh_9" DOUBLE PRECISION DEFAULT NULL, "On_Grid_Hours_Hrs_10" DOUBLE PRECISION DEFAULT NULL, "Fan_On_Time_Hours_Hrs_11" DOUBLE PRECISION DEFAULT NULL, "AC_Contactors_Cycles_12" DOUBLE PRECISION DEFAULT NULL, "Network_ID_13" DOUBLE PRECISION DEFAULT NULL, "Informative_Alarms_14" DOUBLE PRECISION DEFAULT NULL, "Inverter_AC_Output_Current_A_15" DOUBLE PRECISION DEFAULT NULL, "Critical_Alarms_16" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 8.841602 | 8.841602 | 8.841602 | 8.841602 | 0 | 0 | 673 | 1 | 38 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 133 | 36 | 181381 |
| 16385 | 16384 | t | -833164884107262632 | SELECT * FROM "tbl001EC6050F3C_11" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 134 | 6.015840999999998 | 0.017411 | 1.49262 | 0.04489433582089551 | 0.13451695102964753 | 133 | 265 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4519695517080578383 | SET idle_in_transaction_session_timeout = 0 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.056595000000000006 | 0.004041 | 0.01156 | 0.0056595000000000005 | 0.0021261172239554435 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8536972362520461591 | COPY public."tbl001EC605309C_51" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 3848.9138639999996 | 330.165482 | 455.634839 | 384.8913864 | 40.16514280567111 | 324420 | 1602 | 28456 | 118 | 3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3328035025892249135 | SELECT * FROM "tbl001EC6050B08_1" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 2086 | 71.87020799999999 | 0.012577 | 4.220903 | 0.03445359923298173 | 0.16969610272470168 | 2086 | 6222 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5065827165977874471 | INSERT INTO "tbl001EC6050F42_2" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 73 | 4.676282999999998 | 0.021985 | 0.275939 | 0.06405867123287672 | 0.04755406983204006 | 73 | 332 | 2 | 147 | 7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 220 | 135 | 359078 |
| 16385 | 16384 | t | 8127049249199415116 | SELECT setconfig[$1] FROM pg_db_role_setting WHERE setrole = $2 AND setdatabase = $3::oid | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.048915999999999994 | 0.004207 | 0.005725 | 0.0048916 | 0.00043296886724105246 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 555876327915940941 | SELECT * FROM "tbl001EC6053113_53" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 28608 | 1177.4925880000008 | 0.020284 | 6.245522 | 0.04115955634787458 | 0.06824310418311703 | 28608 | 85803 | 21 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | 5419322566926853521 | DROP TABLE IF EXISTS _5001befeeb31fb8114be059bfe6a816a | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2.462067 | 2.462067 | 2.462067 | 2.462067 | 0 | 0 | 2 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -400283940301207954 | INSERT INTO "tbl001EC6050F3C_4" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 67 | 4.5466789999999975 | 0.028147 | 1.484271 | 0.06786088059701491 | 0.17521891492265418 | 67 | 269 | 0 | 133 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 202 | 130 | 196715 |
| 16385 | 16384 | t | -5906382256541712782 | COPY public."tbl001EC6056300_52" ("time", error, lowrange, highrange, "VAB_V_1", "VBC_V_2", "VCA_V_3", "Current_A_A_4", "Current_B_A_5", "Current_C_A_6", "Real_Power_kW_7", "PV_Voltage_V_8", "PV_Current_A_9", "PV_Power_kW_10", "Grid_Frequency_Hz_11", "System_State_12", "Goal_State_13", "Fault_Code_14", "Accumulated_Energy_kWh_15", "R_Matrix_Temp_Degrees_C_16", "L_Matrix_Temp_Degrees_C_17", "Intake_Air_Temperature_Degrees_C_18") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 12686.431788 | 1154.915453 | 1897.631174 | 1268.6431788 | 213.74949864979567 | 2140590 | 218 | 59710 | 15 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4940492110182687977 | SELECT * FROM "tbl001EC6050D16_4" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1908 | 54.824782000000006 | 0.006016 | 3.145933 | 0.028734162473794563 | 0.09335747001219785 | 1907 | 5714 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3887293030408696172 | LOCK TABLE public."tbl001EC6053093_53" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.220486 | 0.018446 | 0.025202 | 0.0220486 | 0.0017851504250342598 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5591777891024624638 | SELECT * FROM "tbl001EC605309C_55" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 4.203531 | 1.314736 | 2.888795 | 2.1017655 | 0.7870295 | 200 | 103 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1695433075765582741 | CREATE TABLE IF NOT EXISTS "tbl001EC6050BAC_52" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Analog_In_1_1" DOUBLE PRECISION DEFAULT NULL, "Analog_In_2_2" DOUBLE PRECISION DEFAULT NULL, "Analog_In_3_3" DOUBLE PRECISION DEFAULT NULL, "Analog_In_4_4" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_5" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_6" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_7" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_8" DOUBLE PRECISION DEFAULT NULL, "Status_register_9" DOUBLE PRECISION DEFAULT NULL, "firmware_version_10" DOUBLE PRECISION DEFAULT NULL, "Uptime_Seconds_11" DOUBLE PRECISION DEFAULT NULL, "Pulse_State_Register_12" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_ontime_Sec_sec_13" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_ontime_Sec_sec_14" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_ontime_Sec_sec_15" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_ontime_Sec_sec_16" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_last_minute_change_17" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_last_minute_change_18" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_last_minute_change_19" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_last_minute_change_20" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 9.162309 | 9.162309 | 9.162309 | 9.162309 | 0 | 0 | 761 | 6 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 141 | 8 | 37469 |
| 16385 | 16384 | t | 2133707498480341402 | INSERT INTO "tbl001EC6050F3C_18" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 67 | 3.522931 | 0.027982 | 0.25732 | 0.05258105970149253 | 0.03285995390158584 | 67 | 269 | 0 | 133 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 202 | 130 | 196715 |
| 16385 | 16384 | t | -5665416323045123137 | COPY public."tbl001EC605311A_3" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 1273.665496 | 113.113369 | 141.334066 | 127.36654959999998 | 9.268090539853334 | 405010 | 95 | 8733 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -671103341530859201 | SELECT * FROM "tbl001EC6053075_6" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1586 | 30.925256999999984 | 0.0062380000000000005 | 0.17703400000000002 | 0.019498901008827244 | 0.010108122753192384 | 1585 | 3946 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1348311984683174184 | SELECT * FROM "tbl001EC6053075_54" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 1.3079180000000001 | 0.026506 | 0.362285 | 0.18684542857142858 | 0.11068717350373032 | 508 | 77 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5088373729513854179 | CREATE TABLE IF NOT EXISTS "tbl001EC6050BAC_10" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "DC_Voltage_V_1" DOUBLE PRECISION DEFAULT NULL, "Apparent_AC_Power_VA_2" DOUBLE PRECISION DEFAULT NULL, "AC_Grid_Frequency_Hz_3" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Stage_Current_A_4" DOUBLE PRECISION DEFAULT NULL, "L1_to_L2_AC_Voltage_V_5" DOUBLE PRECISION DEFAULT NULL, "L2_to_L3_AC_Voltage_V_6" DOUBLE PRECISION DEFAULT NULL, "L1_to_L3_AC_Voltage_V_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Sequence_8" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_kWh_9" DOUBLE PRECISION DEFAULT NULL, "On_Grid_Hours_Hrs_10" DOUBLE PRECISION DEFAULT NULL, "Fan_On_Time_Hours_Hrs_11" DOUBLE PRECISION DEFAULT NULL, "AC_Contactors_Cycles_12" DOUBLE PRECISION DEFAULT NULL, "Network_ID_13" DOUBLE PRECISION DEFAULT NULL, "Informative_Alarms_14" DOUBLE PRECISION DEFAULT NULL, "Inverter_AC_Output_Current_A_15" DOUBLE PRECISION DEFAULT NULL, "Critical_Alarms_16" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.262694 | 6.262694 | 6.262694 | 6.262694 | 0 | 0 | 544 | 2 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 137 | 2 | 16235 |
| 16385 | 16384 | t | -5096014671239453740 | SELECT * FROM "tbl001EC6053113_10" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 28608 | 716.1005640000042 | 0.01448 | 4.524375 | 0.025031479446308805 | 0.05096597602994959 | 28608 | 85803 | 21 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 8679524522967577531 | LOCK TABLE public."tbl001EC6050D16_52" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.14518899999999998 | 0.017192 | 0.03684 | 0.024198166666666666 | 0.00775950813339494 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5430929091461234815 | COPY public."tbl001EC6056D49_9" ("time", error, lowrange, highrange, "Active_Power_Total_kW_1", "Reactive_Power_Total_kVAR_2", "Apparent_Power_Total_kVA_3", "Voltage_Average_Volts_4", "Voltage_L_L_Average_Volts_5", "Current_Average_Amps_6", "System_Power_Factor_7", "System_Frequency_Hz_8", "Voltage_Average_Angle_Degrees_9", "System_Quadrant_10", "Voltage_A_Volts_11", "Voltage_B_Volts_12", "Voltage_C_Volts_13", "Voltage_A_B_Volts_14", "Voltage_B_C_Volts_15", "Voltage_A_C_Volts_16", "Current_A_Amps_17", "Current_B_Amps_18", "Current_C_Amps_19", "Active_Power_A_kW_20", "Active_Power_B_kW_21", "Active_Power_C_kW_22", "Reactive_Power_A_kVAR_23", "Reactive_Power_B_kVAR_24", "Reactive_Power_C_kVAR_25", "Apparent_Power_A_kVA_26", "Apparent_Power_B_kVA_27", "Apparent_Power_C_kVA_28", "Power_Factor_A_29", "Power_Factor_B_30", "Power_Factor_C_31", "Voltage_Angle_AB_Degrees_32", "Voltage_Angle_BC_Degrees_33", "Voltage_Angle_CA_Degrees_34", "Quadrant_A_35", "Quadrant_B_36", "Quadrant_C_37", "Sliding_Window_Power_kW_38", "Net_Total_Energy_Revenue_kWh_39", "Total_Net_Apparent_Energy_Revenue_kVA_40", "Total_Import_Energy_Revenue_kWh_41", "Total_Export_Energy_Revenue_kWh_42", "Total_Import_Apparent_Energy_Revenue_kVA_43", "Total_Export_Apparent_Energy_Revenue_kVA_44", "Q1_Total_Reactive_Energy_Revenue_kVAR_45", "Q2_Total_Reactive_Energy_Revenue_kVAR_46", "Q3_Total_Reactive_Energy_Revenue_kVAR_47", "Q4_Total_Reactive_Energy_Revenue_kVAR_48", "Q1_Q2_Total_Inductive_Reactive_Energy_Revenue_kVAR_49", "Q3_Q4_Total_Capacitive_Reactive_Energy_Revenue_kVAR_50", "Net_Energy_Revenue_A_kWh_51", "Net_Energy_Revenue_B_kWh_52", "Net_Energy_Revenue_C_kWh_53", "Net_Apparent_Energy_Revenue_A_kVA_54", "Net_Apparent_Energy_Revenue_B_kVA_55", "Net_Apparent_Energy_Revenue_C_kVA_56", "Import_Energy_Revenue_A_kWh_57", "Import_Energy_Revenue_B_kWh_58", "Import_Energy_Revenue_C_kWh_59", "Export_Energy_Revenue_A_kWh_60", "Export_Energy_Revenue_B_kWh_61", "Export_Energy_Revenue_C_kWh_62", "Import_Apparent_Energy_Revenue_A_kVA_63", "Import_Apparent_Energy_Revenue_B_kVA_64", "Import_Apparent_Energy_Revenue_C_kVA_65", "Export_Apparent_Energy_Revenue_A_kVA_66", "Export_Apparent_Energy_Revenue_B_kVA_67", "Export_Apparent_Energy_Revenue_C_kVA_68", "Q1_Reactive_Energy_Revenue_A_kVAR_69", "Q1_Reactive_Energy_Revenue_B_kVAR_70", "Q1_Reactive_Energy_Revenue_C_kVAR_71", "Q2_Reactive_Energy_Revenue_A_kVAR_72", "Q2_Reactive_Energy_Revenue_B_kVAR_73", "Q2_Reactive_Energy_Revenue_C_kVAR_74", "Q3_Reactive_Energy_Revenue_A_kVAR_75", "Q3_Reactive_Energy_Revenue_B_kVAR_76", "Q3_Reactive_Energy_Revenue_C_kVAR_77", "Q4_Reactive_Energy_Revenue_A_kVAR_78", "Q4_Reactive_Energy_Revenue_B_kVAR_79", "Q4_Reactive_Energy_Revenue_C_kVAR_80") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 5354.860044999999 | 342.516859 | 731.450687 | 535.4860045 | 118.57641054647725 | 213100 | 14 | 19685 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6875482623069882922 | INSERT INTO "tbl001EC6050F3C_5" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 67 | 4.383229999999999 | 0.028305 | 0.902343 | 0.0654213432835821 | 0.10721249906868972 | 67 | 269 | 0 | 133 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 202 | 130 | 196715 |
| 16385 | 16384 | t | -3743008901551969697 | COPY _timescaledb_catalog.continuous_aggs_bucket_function (mat_hypertable_id, bucket_func, bucket_width, bucket_origin, bucket_offset, bucket_timezone, bucket_fixed_width) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.245847 | 0.02208 | 0.029174 | 0.0245847 | 0.0018612609193769689 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6386363180368678463 | LOCK TABLE public."tbl001EC6053109_7" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 0.075461 | 0.018563 | 0.03451 | 0.025153666666666668 | 0.006797714632302699 | 0 | 18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2357379859879618926 | COPY _timescaledb_catalog.dimension (id, hypertable_id, column_name, column_type, aligned, num_slices, partitioning_func_schema, partitioning_func, interval_length, compress_interval_length, integer_now_func_schema, integer_now_func) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.424215 | 0.038076 | 0.050696 | 0.0424215 | 0.004210225938117811 | 10 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1793748918616321286 | COPY public."tbl001EC6053093_53" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 29776.995727999998 | 2635.26065 | 3460.946896 | 2977.6995728 | 240.53547347951468 | 2124170 | 12785 | 194013 | 48 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5659078131310015898 | COPY public."tbl001EC6050F42_2" ("time", error, lowrange, highrange, "Vln_a_Volts_1", "Vln_b_Volts_2", "Vln_c_Volts_3", "Vln_ave_Volts_4", "Vll_ab_Volts_5", "Vll_bc_Volts_6", "Vll_ca_Volts_7", "Vll_ave_Volts_8", "I_a_Amps_9", "I_b_Amps_10", "I_c_Amps_11", "I_ave_Amps_12", "V_unbal_13", "I_unbal_14", "Freq_Hz_15", "I4_Amps_16", "kW_a_kW_17", "kW_b_kW_18", "kW_c_kW_19", "kW_tot_kW_20", "kVAR_a_kVAR_21", "kVAR_b_kVAR_22", "kVAR_c_kVAR_23", "kVAR_tot_kVAR_24", "kVA_a_kVA_25", "kVA_b_kVA_26", "kVA_c_kVA_27", "kVA_tot_kVA_28", "PF_sign_a_29", "PF_sign_b_30", "PF_sign_c_31", "PF_sign_tot_32", "Vll_ave_mx_Volts_33", "I_ave_mx_Amps_34", "kW_tot_mx_kW_35", "kVAR_tot_mx_kVAR_36", "kVA_tot_mx_kVA_37", "Freq_mx_Hz_38", "Vll_ave_mn_Volts_39", "I_ave_mn_Amps_40", "Freq_mn_Hz_41", "kW_sd_del_rec_kW_42", "kVA_sd_del_rec_kVA_43", "kVAR_sd_del_rec_kVAR_44", "kW_sd_mx_d_r_kW_45", "kVA_sd_mx_d_r_kVA_46", "kVAR_sd_mx_d_r_kVAR_47", "Phase_Rev_48", "kWh_del_kWh_49", "kWh_rec_kWh_50", "kWh_del_rec_kWh_51", "kWh_del_rec_kWh_52", "kVARh_del_kVARh_53", "kVARh_rec_kVARh_54", "kVARh_del_rec_kVARh_55", "kVARh_del_rec_kVARh_56", "kVAh_del_rec_kVAh_57", "V1_THD_mx_58", "V2_THD_mx_59", "V3_THD_mx_60", "I1_THD_mx_61", "I2_THD_mx_62", "I3_THD_mx_63", unused_64) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.149974 | 0.149974 | 0.149974 | 0.149974 | 0 | 13 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 8921681041354551030 | LOCK TABLE public."tbl001EC6056300_15" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.40178499999999995 | 0.019207 | 0.189996 | 0.0401785 | 0.05026624920411309 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | 8584207651148466389 | DROP TABLE IF EXISTS _4a37bb5125f01151dc7937865e2037fe | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1.34558 | 1.34558 | 1.34558 | 1.34558 | 0 | 0 | 5 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7738153563484438493 | CREATE TABLE IF NOT EXISTS "tbl001EC6053075_53" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Operating_State_I_Status_1" DOUBLE PRECISION DEFAULT NULL, "Vendor_Operating_State_I_Status_Vendor_2" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_1_bits_0_31_3" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_2_bits_32_63_4" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8" DOUBLE PRECISION DEFAULT NULL, "AC_Total_Current_I_AC_Current_A_9" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_A_Current_I_AC_CurrentA_A_10" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_B_Current_I_AC_CurrentB_A_11" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_C_Current_I_AC_CurrentC_A_12" DOUBLE PRECISION DEFAULT NULL, "ac_current_Scale_Factor_I_AC_Current_SF_13" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19" DOUBLE PRECISION DEFAULT NULL, "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20" DOUBLE PRECISION DEFAULT NULL, "AC_Power_I_AC_Power_W_21" DOUBLE PRECISION DEFAULT NULL, "ac_power_Scale_Factor_I_AC_Power_SF_22" DOUBLE PRECISION DEFAULT NULL, "AC_Frequency_I_AC_Frequency_Hz_23" DOUBLE PRECISION DEFAULT NULL, "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24" DOUBLE PRECISION DEFAULT NULL, "Apparent_Power_I_AC_VA_VA_25" DOUBLE PRECISION DEFAULT NULL, "apparent_power_Scale_Factor_I_AC_VA_SF_26" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_I_AC_VAR_Var_27" DOUBLE PRECISION DEFAULT NULL, "reactive_power_Scale_Factor_I_AC_VAR_28" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_I_AC_PF_29" DOUBLE PRECISION DEFAULT NULL, "power_factor_Scale_Factor_I_AC_PF_SF_30" DOUBLE PRECISION DEFAULT NULL, "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31" DOUBLE PRECISION DEFAULT NULL, "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32" DOUBLE PRECISION DEFAULT NULL, "DC_Current_I_DC_Current_A_33" DOUBLE PRECISION DEFAULT NULL, "dc_current_Scale_Factor_I_DC_Current_SF_34" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_I_DC_Voltage_V_35" DOUBLE PRECISION DEFAULT NULL, "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36" DOUBLE PRECISION DEFAULT NULL, "DC_Power_I_DC_Power_W_37" DOUBLE PRECISION DEFAULT NULL, "dc_power_Scale_Factor_I_DC_Power_SF_38" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_I_Temp_Cab_Deg_C_39" DOUBLE PRECISION DEFAULT NULL, "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_I_Temp_Trans_Deg_C_41" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_I_Temp_Other_Deg_C_42" DOUBLE PRECISION DEFAULT NULL, "temperature_Scale_Factor_I_Temp_SF_43" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_ID_44" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_Model_Block_45" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_46" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_1_47" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_2_48" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_3_49" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_4_50" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_5_51" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_6_52" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_7_53" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_8_54" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_1_55" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_2_56" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_3_57" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_4_58" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_5_59" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_6_60" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_7_61" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_8_62" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_1_63" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_2_64" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_3_65" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_4_66" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_1_67" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_2_68" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_3_69" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_4_70" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_1_71" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_2_72" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_3_73" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_4_74" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_5_75" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_6_76" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_7_77" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_8_78" DOUBLE PRECISION DEFAULT NULL, "C_DeviceAddress_Modbus_ID_79" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_End_Block_matches_FFFF_80" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_Last_Block_matches_0_81" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 7.505778 | 7.505778 | 7.505778 | 7.505778 | 0 | 0 | 1141 | 4 | 7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 281 | 4 | 42708 |
| 16385 | 16384 | t | 5721938458941409627 | SELECT * FROM "tbl001EC6053113_52" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 1.912614 | 0.707211 | 1.205403 | 0.956307 | 0.24909599999999998 | 200 | 105 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1633178077259222686 | INSERT INTO "tbl001EC6050F3C_8" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 67 | 3.3109530000000005 | 0.027777 | 0.175968 | 0.049417208955223876 | 0.02540846761286382 | 67 | 269 | 0 | 133 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 202 | 130 | 196715 |
| 16385 | 16384 | t | -8726540687649906607 | SELECT * FROM "tbl001EC6056D47_52" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 28976 | 1165.3830040000082 | 0.021537999999999998 | 3.7724830000000003 | 0.04021890543898416 | 0.04001152675001235 | 28976 | 86924 | 4 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1553526116437692926 | INSERT INTO "tbl001EC6050B42_51" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 550 | 38.221948000000026 | 0.018815 | 1.9189980000000002 | 0.06949445090909097 | 0.12995457586867662 | 550 | 2801 | 12 | 1083 | 19 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1652 | 1073 | 4360005 |
| 16385 | 16384 | t | 7036321271409917878 | SELECT * FROM "tbl001EC6050F3C_5" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 134 | 5.323659 | 0.014346 | 1.298497 | 0.03972879850746267 | 0.11108499459602857 | 133 | 265 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6767376687663829001 | SELECT * FROM "tbl001EC6050D06_2" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 8.090047 | 0.13309300000000002 | 6.994403 | 1.3483411666666667 | 2.5257465863128084 | 600 | 566 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6770469974461588436 | LOCK TABLE public."tbl001EC6056D48_52" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.32016300000000003 | 0.018918 | 0.070846 | 0.032016300000000004 | 0.013556688216891323 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1448348365787151770 | LOCK TABLE public."tbl001EC6050D06_2" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.15880799999999998 | 0.018583 | 0.042809 | 0.026468 | 0.008253711569146737 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4221947877590446308 | LOCK TABLE public."tbl001EC6056FD2_55" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.31564699999999996 | 0.018908 | 0.093134 | 0.0315647 | 0.02173667101029962 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2775730264983670673 | INSERT INTO "tbl001EC6056D41_51" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 3005 | 206.36253200000002 | 0.020726 | 2.108851 | 0.06867305557404321 | 0.10082123833709619 | 3005 | 20126 | 29 | 5969 | 248 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 9024 | 5558 | 25642065 |
| 16385 | 16384 | t | 7793476847128156026 | CREATE TABLE IF NOT EXISTS "tbl001EC6050B87_1" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Operating_State_I_Status_1" DOUBLE PRECISION DEFAULT NULL, "Vendor_Operating_State_I_Status_Vendor_2" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_1_bits_0_31_3" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_2_bits_32_63_4" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8" DOUBLE PRECISION DEFAULT NULL, "AC_Total_Current_I_AC_Current_A_9" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_A_Current_I_AC_CurrentA_A_10" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_B_Current_I_AC_CurrentB_A_11" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_C_Current_I_AC_CurrentC_A_12" DOUBLE PRECISION DEFAULT NULL, "ac_current_Scale_Factor_I_AC_Current_SF_13" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19" DOUBLE PRECISION DEFAULT NULL, "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20" DOUBLE PRECISION DEFAULT NULL, "AC_Power_I_AC_Power_W_21" DOUBLE PRECISION DEFAULT NULL, "ac_power_Scale_Factor_I_AC_Power_SF_22" DOUBLE PRECISION DEFAULT NULL, "AC_Frequency_I_AC_Frequency_Hz_23" DOUBLE PRECISION DEFAULT NULL, "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24" DOUBLE PRECISION DEFAULT NULL, "Apparent_Power_I_AC_VA_VA_25" DOUBLE PRECISION DEFAULT NULL, "apparent_power_Scale_Factor_I_AC_VA_SF_26" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_I_AC_VAR_Var_27" DOUBLE PRECISION DEFAULT NULL, "reactive_power_Scale_Factor_I_AC_VAR_28" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_I_AC_PF_29" DOUBLE PRECISION DEFAULT NULL, "power_factor_Scale_Factor_I_AC_PF_SF_30" DOUBLE PRECISION DEFAULT NULL, "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31" DOUBLE PRECISION DEFAULT NULL, "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32" DOUBLE PRECISION DEFAULT NULL, "DC_Current_I_DC_Current_A_33" DOUBLE PRECISION DEFAULT NULL, "dc_current_Scale_Factor_I_DC_Current_SF_34" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_I_DC_Voltage_V_35" DOUBLE PRECISION DEFAULT NULL, "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36" DOUBLE PRECISION DEFAULT NULL, "DC_Power_I_DC_Power_W_37" DOUBLE PRECISION DEFAULT NULL, "dc_power_Scale_Factor_I_DC_Power_SF_38" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_I_Temp_Cab_Deg_C_39" DOUBLE PRECISION DEFAULT NULL, "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_I_Temp_Trans_Deg_C_41" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_I_Temp_Other_Deg_C_42" DOUBLE PRECISION DEFAULT NULL, "temperature_Scale_Factor_I_Temp_SF_43" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_ID_44" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_Model_Block_45" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_46" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_1_47" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_2_48" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_3_49" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_4_50" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_5_51" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_6_52" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_7_53" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_8_54" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_1_55" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_2_56" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_3_57" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_4_58" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_5_59" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_6_60" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_7_61" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_8_62" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_1_63" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_2_64" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_3_65" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_4_66" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_1_67" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_2_68" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_3_69" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_4_70" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_1_71" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_2_72" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_3_73" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_4_74" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_5_75" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_6_76" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_7_77" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_8_78" DOUBLE PRECISION DEFAULT NULL, "C_DeviceAddress_Modbus_ID_79" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_End_Block_matches_FFFF_80" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_Last_Block_matches_0_81" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 41.037324 | 41.037324 | 41.037324 | 41.037324 | 0 | 0 | 1352 | 63 | 42 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 281 | 38 | 199061 |
| 16385 | 16384 | t | -4296785646270357210 | CREATE TABLE IF NOT EXISTS "tbl001EC6050B5D_51" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Analog_In_1_1" DOUBLE PRECISION DEFAULT NULL, "Analog_In_2_2" DOUBLE PRECISION DEFAULT NULL, "Analog_In_3_3" DOUBLE PRECISION DEFAULT NULL, "Analog_In_4_4" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_5" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_6" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_7" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_8" DOUBLE PRECISION DEFAULT NULL, "Status_register_9" DOUBLE PRECISION DEFAULT NULL, "firmware_version_10" DOUBLE PRECISION DEFAULT NULL, "Uptime_Seconds_11" DOUBLE PRECISION DEFAULT NULL, "Pulse_State_Register_12" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_ontime_Sec_sec_13" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_ontime_Sec_sec_14" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_ontime_Sec_sec_15" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_ontime_Sec_sec_16" DOUBLE PRECISION DEFAULT NULL, "Pulse_1_last_minute_change_17" DOUBLE PRECISION DEFAULT NULL, "Pulse_2_last_minute_change_18" DOUBLE PRECISION DEFAULT NULL, "Pulse_3_last_minute_change_19" DOUBLE PRECISION DEFAULT NULL, "Pulse_4_last_minute_change_20" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 5.681535 | 5.681535 | 5.681535 | 5.681535 | 0 | 0 | 616 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 154 | 2 | 17759 |
| 16385 | 16384 | t | 3976813820504157459 | SELECT tableoid, oid, conname, confrelid, conindid, pg_catalog.pg_get_constraintdef(oid) AS condef FROM pg_catalog.pg_constraint WHERE conrelid = $1::pg_catalog.oid AND conparentid = $2 AND contype = $3 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.099705 | 0.008932 | 0.011671 | 0.0099705 | 0.0009442258469243471 | 0 | 20 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1782615689316606183 | COPY public."tbl001EC6056D47_50" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 2732.185463 | 205.191515 | 356.28325 | 273.2185463 | 55.442652629052 | 223706 | 191 | 20506 | 75 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | -7987494163966368481 | DROP TABLE IF EXISTS _3b5fd77e4d2a3c4e5d1599d5dc0964b9 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 2.217334 | 2.217334 | 2.217334 | 2.217334 | 0 | 0 | 2 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3101446195258583315 | COPY public."tbl001EC6050F42_51" ("time", error, lowrange, highrange, "umtLastMeasTime_1", "2", "umtWindSpeed_MPH_3", "4", "umtRawWindDir_Degrees_5", "6", "umtAdjWindDir_Degrees_7", "8", "umtRelHumidity_9", "10", "umtRawBaromPress_Inches_Hg_11", "12", "umtAdjBaromPress_Inches_Hg_13", "14", "umtTrueNorthOffset_Degrees_15", "16", "umtLastRain_Date_and_Time_17", "18", "umtTemp1_Degrees_F_19", "20", "umtWindChill_Degrees_F_21", "22", "umtHeatIndex_Degrees_F_23", "24", "umtDewPoint_Degrees_F_25", "26", "umtDensityAltitude_Feet_27", "28", "umtRainToday_Inches_29", "umtTemp2_Degrees_F_30", "umtTemp3_Degrees_F_31", "umtTemp4_Degrees_F_32", "umtSolarRadiation_W_m_2_33", "umtSolarRadiation_2_W_m_2_34", "35", "36", "37", "38", "39", "40", "41", "42", "43", "44", "45", "46", "47", "48", "49", "50", "51", "52") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.0842 | 0.0842 | 0.0842 | 0.0842 | 0 | 13 | 1 | 0 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -9088758989860567972 | LOCK TABLE public."tbl001EC60537E0_41" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 0.6288190000000001 | 0.017229 | 0.470708 | 0.08983128571428571 | 0.15597541852091795 | 0 | 42 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -30883086997045498 | COPY public."tbl001EC6056FD2_10" ("time", error, lowrange, highrange, "Horizontal_Irradiance_W_m_2_1", "POA_Irradiance_W_m_2_2", "Ambient_Temperature_Degrees_F_3", "Module_Temperature_Degrees_F_4", "Future_Use_4_5", "Future_Use_5_6", "Future_Use_6_7", "Future_Use_7_8", "Burnout_0_9", "Burnout_1_10", "Burnout_2_11", "Burnout_3_12", "Burnout_4_13", "Burnout_5_14", "Burnout_6_15", "Burnout_7_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 805.129134 | 58.430443 | 117.596492 | 80.5129134 | 18.579989145532902 | 226930 | 10 | 5729 | 22 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3693731925901927705 | COPY public.conditions ("time", location, temperature, humidity) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.30671899999999996 | 0.020653 | 0.061214 | 0.0306719 | 0.011186094979482336 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6659626453431793390 | COPY public."tbl001EC6050B5D_51" ("time", error, lowrange, highrange, "Analog_In_1_1", "Analog_In_2_2", "Analog_In_3_3", "Analog_In_4_4", "Pulse_1_5", "Pulse_2_6", "Pulse_3_7", "Pulse_4_8", "Status_register_9", firmware_version_10, "Uptime_Seconds_11", "Pulse_State_Register_12", "Pulse_1_ontime_Sec_sec_13", "Pulse_2_ontime_Sec_sec_14", "Pulse_3_ontime_Sec_sec_15", "Pulse_4_ontime_Sec_sec_16", "Pulse_1_last_minute_change_17", "Pulse_2_last_minute_change_18", "Pulse_3_last_minute_change_19", "Pulse_4_last_minute_change_20") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 14.749991000000001 | 0.074737 | 3.864124 | 1.638887888888889 | 1.2721442716464062 | 3554 | 81 | 25 | 7 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5985344997607067513 | SELECT * FROM "tbl001EC6056D49_51" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29112 | 1185.857237000001 | 0.022279 | 6.859843 | 0.04073431014701872 | 0.05503387733206049 | 29112 | 87332 | 4 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8238557535392713271 | COPY public."tbl001EC6050B08_1" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 261.701222 | 14.75383 | 34.704764 | 26.170122199999998 | 7.235933350368146 | 154845 | 418 | 593 | 53 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2584067341849581997 | LOCK TABLE public."tbl001EC6050E0D_1" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.27473600000000004 | 0.017154 | 0.052144 | 0.027473599999999997 | 0.010187470001919025 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3664317575481722212 | LOCK TABLE public."tbl001EC6050189_33" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 0.207395 | 0.017046 | 0.03929 | 0.023043888888888885 | 0.006258892082370924 | 0 | 54 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2479669705263942689 | SELECT last_value, is_called FROM _timescaledb_catalog.chunk_constraint_name | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 5.898623000000001 | 0.023774999999999998 | 1.107976 | 0.5898623000000001 | 0.3237967057062348 | 10 | 2 | 8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -88842803340586162 | INSERT INTO "tbl001EC6056FD2_26" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 15024 | 839.5028070000002 | 0.015529999999999999 | 88.41460099999999 | 0.05587744988019163 | 0.829932293172386 | 15024 | 92509 | 28 | 8169 | 274 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 45114 | 7639 | 35563453 |
| 16385 | 16384 | t | 606364023585675241 | SELECT pg_database.datname, pg_database.datconnlimit FROM pg_database | 0 | 0 | 0 | 0 | 0 | 0 | 118363 | 1213.1032229999967 | 0.006094 | 2.0426960000000003 | 0.010249007063018092 | 0.013041146570600872 | 473452 | 118363 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2171346355479577214 | LOCK TABLE public."tbl001EC6050C0B_1" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.23474899999999999 | 0.027166 | 0.087574 | 0.03912483333333333 | 0.02173633485216759 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -53537418072041312 | SELECT tableoid, oid, prsname, prsnamespace, prsstart::oid, prstoken::oid, prsend::oid, prsheadline::oid, prslextype::oid FROM pg_ts_parser | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 10.840814000000002 | 0.635086 | 1.9703400000000002 | 1.0840813999999999 | 0.5127303876507028 | 10 | 0 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7054673473658507041 | COPY _timescaledb_catalog.continuous_agg (mat_hypertable_id, raw_hypertable_id, parent_mat_hypertable_id, user_view_schema, user_view_name, partial_view_schema, partial_view_name, direct_view_schema, direct_view_name, materialized_only, finalized) TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.28016300000000005 | 0.024784 | 0.036351 | 0.0280163 | 0.003160737035882612 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8838362926510110960 | INSERT INTO "tbl001EC6056D41_55" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 3005 | 203.2110819999997 | 0.021710999999999998 | 2.2203589999999997 | 0.06762432013311168 | 0.09563504173774577 | 3005 | 20113 | 30 | 5954 | 251 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 9024 | 5541 | 25344160 |