pg_stat_statements
|
userid oid |
dbid oid |
toplevel boolean |
queryid bigint |
query text |
plans bigint |
total_plan_time double precision |
min_plan_time double precision |
max_plan_time double precision |
mean_plan_time double precision |
stddev_plan_time double precision |
calls bigint |
total_exec_time double precision |
min_exec_time double precision |
max_exec_time double precision |
mean_exec_time double precision |
stddev_exec_time double precision |
rows bigint |
shared_blks_hit bigint |
shared_blks_read bigint |
shared_blks_dirtied bigint |
shared_blks_written bigint |
local_blks_hit bigint |
local_blks_read bigint |
local_blks_dirtied bigint |
local_blks_written bigint |
temp_blks_read bigint |
temp_blks_written bigint |
blk_read_time double precision |
blk_write_time double precision |
wal_records bigint |
wal_fpi bigint |
wal_bytes numeric |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 16385 | 16384 | t | -8515388520039940802 | SELECT * FROM "tbl001EC6050F3A_51" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 16.474284 | 0.468707 | 4.438079999999999 | 1.830476 | 1.6075604439481168 | 900 | 89 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6697749064237325391 | CREATE TABLE IF NOT EXISTS "tbl001EC6050C0B_3" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Vln_a_Volts_1" DOUBLE PRECISION DEFAULT NULL, "Vln_b_Volts_2" DOUBLE PRECISION DEFAULT NULL, "Vln_c_Volts_3" DOUBLE PRECISION DEFAULT NULL, "Vln_ave_Volts_4" DOUBLE PRECISION DEFAULT NULL, "Vll_ab_Volts_5" DOUBLE PRECISION DEFAULT NULL, "Vll_bc_Volts_6" DOUBLE PRECISION DEFAULT NULL, "Vll_ca_Volts_7" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_Volts_8" DOUBLE PRECISION DEFAULT NULL, "I_a_Amps_9" DOUBLE PRECISION DEFAULT NULL, "I_b_Amps_10" DOUBLE PRECISION DEFAULT NULL, "I_c_Amps_11" DOUBLE PRECISION DEFAULT NULL, "I_ave_Amps_12" DOUBLE PRECISION DEFAULT NULL, "V_unbal_13" DOUBLE PRECISION DEFAULT NULL, "I_unbal_14" DOUBLE PRECISION DEFAULT NULL, "Freq_Hz_15" DOUBLE PRECISION DEFAULT NULL, "I4_Amps_16" DOUBLE PRECISION DEFAULT NULL, "kW_a_kW_17" DOUBLE PRECISION DEFAULT NULL, "kW_b_kW_18" DOUBLE PRECISION DEFAULT NULL, "kW_c_kW_19" DOUBLE PRECISION DEFAULT NULL, "kW_tot_kW_20" DOUBLE PRECISION DEFAULT NULL, "kVAR_a_kVAR_21" DOUBLE PRECISION DEFAULT NULL, "kVAR_b_kVAR_22" DOUBLE PRECISION DEFAULT NULL, "kVAR_c_kVAR_23" DOUBLE PRECISION DEFAULT NULL, "kVAR_tot_kVAR_24" DOUBLE PRECISION DEFAULT NULL, "kVA_a_kVA_25" DOUBLE PRECISION DEFAULT NULL, "kVA_b_kVA_26" DOUBLE PRECISION DEFAULT NULL, "kVA_c_kVA_27" DOUBLE PRECISION DEFAULT NULL, "kVA_tot_kVA_28" DOUBLE PRECISION DEFAULT NULL, "PF_sign_a_29" DOUBLE PRECISION DEFAULT NULL, "PF_sign_b_30" DOUBLE PRECISION DEFAULT NULL, "PF_sign_c_31" DOUBLE PRECISION DEFAULT NULL, "PF_sign_tot_32" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_mx_Volts_33" DOUBLE PRECISION DEFAULT NULL, "I_ave_mx_Amps_34" DOUBLE PRECISION DEFAULT NULL, "kW_tot_mx_kW_35" DOUBLE PRECISION DEFAULT NULL, "kVAR_tot_mx_kVAR_36" DOUBLE PRECISION DEFAULT NULL, "kVA_tot_mx_kVA_37" DOUBLE PRECISION DEFAULT NULL, "Freq_mx_Hz_38" DOUBLE PRECISION DEFAULT NULL, "Vll_ave_mn_Volts_39" DOUBLE PRECISION DEFAULT NULL, "I_ave_mn_Amps_40" DOUBLE PRECISION DEFAULT NULL, "Freq_mn_Hz_41" DOUBLE PRECISION DEFAULT NULL, "kW_sd_del_rec_kW_42" DOUBLE PRECISION DEFAULT NULL, "kVA_sd_del_rec_kVA_43" DOUBLE PRECISION DEFAULT NULL, "kVAR_sd_del_rec_kVAR_44" DOUBLE PRECISION DEFAULT NULL, "kW_sd_mx_d_r_kW_45" DOUBLE PRECISION DEFAULT NULL, "kVA_sd_mx_d_r_kVA_46" DOUBLE PRECISION DEFAULT NULL, "kVAR_sd_mx_d_r_kVAR_47" DOUBLE PRECISION DEFAULT NULL, "Phase_Rev_48" DOUBLE PRECISION DEFAULT NULL, "kWh_del_kWh_49" DOUBLE PRECISION DEFAULT NULL, "kWh_rec_kWh_50" DOUBLE PRECISION DEFAULT NULL, "kWh_del_rec_kWh_51" DOUBLE PRECISION DEFAULT NULL, "kWh_del_rec_kWh_52" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_kVARh_53" DOUBLE PRECISION DEFAULT NULL, "kVARh_rec_kVARh_54" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_rec_kVARh_55" DOUBLE PRECISION DEFAULT NULL, "kVARh_del_rec_kVARh_56" DOUBLE PRECISION DEFAULT NULL, "kVAh_del_rec_kVAh_57" DOUBLE PRECISION DEFAULT NULL, "V1_THD_mx_58" DOUBLE PRECISION DEFAULT NULL, "V2_THD_mx_59" DOUBLE PRECISION DEFAULT NULL, "V3_THD_mx_60" DOUBLE PRECISION DEFAULT NULL, "I1_THD_mx_61" DOUBLE PRECISION DEFAULT NULL, "I2_THD_mx_62" DOUBLE PRECISION DEFAULT NULL, "I3_THD_mx_63" DOUBLE PRECISION DEFAULT NULL, "unused_64" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.63966 | 6.63966 | 6.63966 | 6.63966 | 0 | 0 | 919 | 1 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 231 | 2 | 29041 |
| 16385 | 16384 | t | 1147616880456321454 | select $1 | 0 | 0 | 0 | 0 | 0 | 0 | 12876 | 85.31328800000007 | 0.002529 | 2.5454369999999997 | 0.006625760173967062 | 0.040140959604490656 | 12876 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1925131941256678950 | COPY public."tbl001EC6050F3C_11" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.113406 | 0.113406 | 0.113406 | 0.113406 | 0 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7813956922670189257 | SELECT * FROM "tbl001EC6050B87_2" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 12696 | 502.4794739999998 | 0.009829000000000001 | 11.060923 | 0.03957777835538749 | 0.10006659401240925 | 12695 | 37274 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7138112801914314736 | COPY public."tbl001EC6050F3C_7" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.153831 | 0.153831 | 0.153831 | 0.153831 | 0 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | -9146164936648527847 | CREATE TABLE _d66ebbbedcc1b109647008da003a6441(cmd_output text) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 9.918533 | 9.918533 | 9.918533 | 9.918533 | 0 | 0 | 509 | 10 | 30 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 96 | 28 | 150062 |
| 16385 | 16384 | t | 528332470491693265 | INSERT INTO "tbl001EC6053CD9_2" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 2868 | 165.02515700000012 | 0.022899 | 2.582117 | 0.05754015237099021 | 0.1146304623018859 | 2868 | 17437 | 57 | 3827 | 59 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 8612 | 3742 | 16167320 |
| 16385 | 16384 | t | 4469410350386105843 | LOCK TABLE public."tbl001EC6053109_11" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 0.09114900000000001 | 0.022978 | 0.044328 | 0.030383 | 0.009866925390752007 | 0 | 18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6318586177638953746 | SELECT tableoid, oid, amname, amtype, amhandler::pg_catalog.regproc AS amhandler FROM pg_am | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 20.650985000000002 | 0.898222 | 4.478457 | 2.0650985000000004 | 1.1870711540291299 | 90 | 533 | 17 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7832173538386086072 | COPY public."tbl001EC6050F3C_16" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.147318 | 0.147318 | 0.147318 | 0.147318 | 0 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5906382256541712782 | COPY public."tbl001EC6056300_52" ("time", error, lowrange, highrange, "VAB_V_1", "VBC_V_2", "VCA_V_3", "Current_A_A_4", "Current_B_A_5", "Current_C_A_6", "Real_Power_kW_7", "PV_Voltage_V_8", "PV_Current_A_9", "PV_Power_kW_10", "Grid_Frequency_Hz_11", "System_State_12", "Goal_State_13", "Fault_Code_14", "Accumulated_Energy_kWh_15", "R_Matrix_Temp_Degrees_C_16", "L_Matrix_Temp_Degrees_C_17", "Intake_Air_Temperature_Degrees_C_18") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 12686.431788 | 1154.915453 | 1897.631174 | 1268.6431788 | 213.74949864979567 | 2140590 | 218 | 59710 | 15 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6156484424927834411 | INSERT INTO "tbl001EC6056FD2_52" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 15066 | 650.065407 | 0.014646 | 6.942157 | 0.04314784328952609 | 0.09865577271439908 | 15066 | 93220 | 45 | 8646 | 297 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 45239 | 7966 | 39047954 |
| 16385 | 16384 | t | -5665416323045123137 | COPY public."tbl001EC605311A_3" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 1273.665496 | 113.113369 | 141.334066 | 127.36654959999998 | 9.268090539853334 | 405010 | 95 | 8733 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -671103341530859201 | SELECT * FROM "tbl001EC6053075_6" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1602 | 31.234725999999988 | 0.0062380000000000005 | 0.17703400000000002 | 0.01949733208489388 | 0.010063282581205564 | 1601 | 3994 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7404312500466120700 | SELECT provider, label FROM pg_catalog.pg_shseclabel WHERE classoid = $1::pg_catalog.regclass AND objoid = $2 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.078907 | 0.006304 | 0.009492 | 0.007890700000000002 | 0.0009334975147262044 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1348311984683174184 | SELECT * FROM "tbl001EC6053075_54" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 8 | 2.162814 | 0.026506 | 0.854896 | 0.27035175 | 0.24399453705090918 | 608 | 101 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -766830977261832433 | INSERT INTO "tbl001EC6050B5D_1" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 842 | 57.063598999999925 | 0.018715 | 1.397014 | 0.06777149524940626 | 0.12226726122263536 | 842 | 4694 | 18 | 1641 | 18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 2529 | 1616 | 7041660 |
| 16385 | 16384 | t | 8679524522967577531 | LOCK TABLE public."tbl001EC6050D16_52" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.14518899999999998 | 0.017192 | 0.03684 | 0.024198166666666666 | 0.00775950813339494 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -6321992910413967866 | INSERT INTO "tbl001EC6050B42_2" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 552 | 39.817029999999995 | 0.019457 | 2.8517740000000003 | 0.07213230072463775 | 0.17506994546716734 | 552 | 2790 | 15 | 1095 | 12 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1658 | 1082 | 4442744 |
| 16385 | 16384 | t | 1756723268131439378 | INSERT INTO "tbl001EC6050F3C_54" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 70 | 3.276786 | 0.026224 | 0.220557 | 0.04681122857142857 | 0.02706292432048552 | 70 | 281 | 0 | 139 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 211 | 136 | 194060 |
| 16385 | 16384 | t | 8737305739057262910 | LOCK TABLE public."tbl001EC6056FD2_54" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 1.365387 | 0.017037 | 0.760135 | 0.13653869999999999 | 0.23562981058391147 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6386363180368678463 | LOCK TABLE public."tbl001EC6053109_7" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 0.075461 | 0.018563 | 0.03451 | 0.025153666666666668 | 0.006797714632302699 | 0 | 18 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7126306129629372151 | CREATE TABLE IF NOT EXISTS "tbl001EC6050BAC_9" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "DC_Voltage_V_1" DOUBLE PRECISION DEFAULT NULL, "Apparent_AC_Power_VA_2" DOUBLE PRECISION DEFAULT NULL, "AC_Grid_Frequency_Hz_3" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Stage_Current_A_4" DOUBLE PRECISION DEFAULT NULL, "L1_to_L2_AC_Voltage_V_5" DOUBLE PRECISION DEFAULT NULL, "L2_to_L3_AC_Voltage_V_6" DOUBLE PRECISION DEFAULT NULL, "L1_to_L3_AC_Voltage_V_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Sequence_8" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_kWh_9" DOUBLE PRECISION DEFAULT NULL, "On_Grid_Hours_Hrs_10" DOUBLE PRECISION DEFAULT NULL, "Fan_On_Time_Hours_Hrs_11" DOUBLE PRECISION DEFAULT NULL, "AC_Contactors_Cycles_12" DOUBLE PRECISION DEFAULT NULL, "Network_ID_13" DOUBLE PRECISION DEFAULT NULL, "Informative_Alarms_14" DOUBLE PRECISION DEFAULT NULL, "Inverter_AC_Output_Current_A_15" DOUBLE PRECISION DEFAULT NULL, "Critical_Alarms_16" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.21807 | 6.21807 | 6.21807 | 6.21807 | 0 | 0 | 526 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 133 | 1 | 14988 |
| 16385 | 16384 | t | -9184683826705905035 | SELECT * FROM "tbl001EC6050F3C_54" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 140 | 4.485455999999998 | 0.014367 | 1.279051 | 0.03203897142857144 | 0.10679719617453463 | 139 | 277 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2603265693240875346 | SELECT *, (case pg_is_in_recovery() when $1 then pg_last_wal_receive_lsn() else pg_current_wal_lsn() end) AS pg_current_wal_lsn, (case pg_is_in_recovery() when $2 then pg_wal_lsn_diff(pg_last_wal_receive_lsn(), pg_lsn($3))::float else pg_wal_lsn_diff(pg_current_wal_lsn(), pg_lsn($4))::float end) AS pg_current_wal_lsn_bytes, (case pg_is_in_recovery() when $5 then pg_wal_lsn_diff(pg_last_wal_receive_lsn(), replay_lsn)::float else pg_wal_lsn_diff(pg_current_wal_lsn(), replay_lsn)::float end) AS pg_wal_lsn_diff FROM pg_stat_replication | 0 | 0 | 0 | 0 | 0 | 0 | 118739 | 12320.547627999804 | 0.039757 | 18.494588999999998 | 0.10376159162532927 | 0.17328065675880602 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5721938458941409627 | SELECT * FROM "tbl001EC6053113_52" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 1.912614 | 0.707211 | 1.205403 | 0.956307 | 0.24909599999999998 | 200 | 105 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7415312029009403757 | COPY public."tbl001EC6053CD9_2" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 53.07885 | 0.418795 | 15.426488 | 8.846475000000002 | 6.44528349415294 | 8118 | 101 | 68 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 6767376687663829001 | SELECT * FROM "tbl001EC6050D06_2" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 9.536955 | 0.13309300000000002 | 6.994403 | 1.3624221428571428 | 2.3386413153497254 | 700 | 812 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -344862433477869160 | INSERT INTO "tbl001EC6050D06_3" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 1651 | 103.98710000000018 | 0.018221 | 1.9439769999999998 | 0.06298431253785577 | 0.12013538298355796 | 1651 | 9814 | 45 | 2640 | 38 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 4958 | 3212 | 12964243 |
| 16385 | 16384 | t | -8649352417678043315 | CREATE TABLE IF NOT EXISTS "tbl001EC6053075_51" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Operating_State_I_Status_1" DOUBLE PRECISION DEFAULT NULL, "Vendor_Operating_State_I_Status_Vendor_2" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_1_bits_0_31_3" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_2_bits_32_63_4" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8" DOUBLE PRECISION DEFAULT NULL, "AC_Total_Current_I_AC_Current_A_9" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_A_Current_I_AC_CurrentA_A_10" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_B_Current_I_AC_CurrentB_A_11" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_C_Current_I_AC_CurrentC_A_12" DOUBLE PRECISION DEFAULT NULL, "ac_current_Scale_Factor_I_AC_Current_SF_13" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19" DOUBLE PRECISION DEFAULT NULL, "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20" DOUBLE PRECISION DEFAULT NULL, "AC_Power_I_AC_Power_W_21" DOUBLE PRECISION DEFAULT NULL, "ac_power_Scale_Factor_I_AC_Power_SF_22" DOUBLE PRECISION DEFAULT NULL, "AC_Frequency_I_AC_Frequency_Hz_23" DOUBLE PRECISION DEFAULT NULL, "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24" DOUBLE PRECISION DEFAULT NULL, "Apparent_Power_I_AC_VA_VA_25" DOUBLE PRECISION DEFAULT NULL, "apparent_power_Scale_Factor_I_AC_VA_SF_26" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_I_AC_VAR_Var_27" DOUBLE PRECISION DEFAULT NULL, "reactive_power_Scale_Factor_I_AC_VAR_28" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_I_AC_PF_29" DOUBLE PRECISION DEFAULT NULL, "power_factor_Scale_Factor_I_AC_PF_SF_30" DOUBLE PRECISION DEFAULT NULL, "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31" DOUBLE PRECISION DEFAULT NULL, "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32" DOUBLE PRECISION DEFAULT NULL, "DC_Current_I_DC_Current_A_33" DOUBLE PRECISION DEFAULT NULL, "dc_current_Scale_Factor_I_DC_Current_SF_34" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_I_DC_Voltage_V_35" DOUBLE PRECISION DEFAULT NULL, "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36" DOUBLE PRECISION DEFAULT NULL, "DC_Power_I_DC_Power_W_37" DOUBLE PRECISION DEFAULT NULL, "dc_power_Scale_Factor_I_DC_Power_SF_38" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_I_Temp_Cab_Deg_C_39" DOUBLE PRECISION DEFAULT NULL, "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_I_Temp_Trans_Deg_C_41" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_I_Temp_Other_Deg_C_42" DOUBLE PRECISION DEFAULT NULL, "temperature_Scale_Factor_I_Temp_SF_43" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_ID_44" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_Model_Block_45" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_46" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_1_47" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_2_48" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_3_49" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_4_50" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_5_51" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_6_52" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_7_53" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_8_54" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_1_55" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_2_56" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_3_57" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_4_58" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_5_59" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_6_60" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_7_61" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_8_62" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_1_63" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_2_64" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_3_65" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_4_66" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_1_67" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_2_68" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_3_69" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_4_70" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_1_71" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_2_72" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_3_73" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_4_74" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_5_75" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_6_76" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_7_77" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_8_78" DOUBLE PRECISION DEFAULT NULL, "C_DeviceAddress_Modbus_ID_79" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_End_Block_matches_FFFF_80" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_Last_Block_matches_0_81" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 8.239034 | 8.239034 | 8.239034 | 8.239034 | 0 | 0 | 1111 | 4 | 5 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 268 | 4 | 44623 |
| 16385 | 16384 | t | 6580032306928099853 | COPY public."tbl001EC6050D16_7" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 606.750661 | 90.553808 | 118.292124 | 101.12511016666667 | 9.35756921403209 | 399188 | 463 | 2126 | 63 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5154023323298851465 | COPY public."tbl001EC6050B87_2" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 336.294082 | 1.889601 | 72.292232 | 37.36600911111111 | 24.017989696112473 | 27378 | 798 | 1747 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8838362926510110960 | INSERT INTO "tbl001EC6056D41_55" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 3013 | 203.55351899999968 | 0.021710999999999998 | 2.2203589999999997 | 0.06755841984732844 | 0.09551719891466204 | 3013 | 20166 | 30 | 5971 | 251 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 9048 | 5557 | 25405008 |
| 16385 | 16384 | t | 1205527832959063458 | SELECT * FROM "tbl001EC6050F42_2" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 146 | 6.416636000000002 | 0.007859 | 0.640653 | 0.0439495616438356 | 0.057964302573643905 | 145 | 289 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4362494592698048597 | CREATE TABLE IF NOT EXISTS "tbl001EC6050C0B_1" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "DC_Voltage_V_1" DOUBLE PRECISION DEFAULT NULL, "Apparent_AC_Power_VA_2" DOUBLE PRECISION DEFAULT NULL, "AC_Grid_Frequency_Hz_3" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Stage_Current_A_4" DOUBLE PRECISION DEFAULT NULL, "L1_to_L2_AC_Voltage_V_5" DOUBLE PRECISION DEFAULT NULL, "L2_to_L3_AC_Voltage_V_6" DOUBLE PRECISION DEFAULT NULL, "L1_to_L3_AC_Voltage_V_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Sequence_8" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_kWh_9" DOUBLE PRECISION DEFAULT NULL, "On_Grid_Hours_Hrs_10" DOUBLE PRECISION DEFAULT NULL, "Fan_On_Time_Hours_Hrs_11" DOUBLE PRECISION DEFAULT NULL, "AC_Contactors_Cycles_12" DOUBLE PRECISION DEFAULT NULL, "Network_ID_13" DOUBLE PRECISION DEFAULT NULL, "Informative_Alarms_14" DOUBLE PRECISION DEFAULT NULL, "Inverter_AC_Output_Current_A_15" DOUBLE PRECISION DEFAULT NULL, "Critical_Alarms_16" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 13.813663 | 13.813663 | 13.813663 | 13.813663 | 0 | 0 | 737 | 6 | 41 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 134 | 37 | 171442 |
| 16385 | 16384 | t | -350276456921446411 | SELECT at.attname, at.attnum, ty.typname FROM pg_catalog.pg_attribute at LEFT JOIN pg_catalog.pg_type ty ON (ty.oid = at.atttypid) JOIN pg_catalog.pg_class as cl ON cl.oid=AT.attrelid JOIN pg_catalog.pg_namespace as nsp ON nsp.oid=cl.relnamespace WHERE cl.relname = $1 AND nsp.nspname=$2 AND attnum = ANY ( (SELECT con.conkey FROM pg_catalog.pg_class rel LEFT OUTER JOIN pg_catalog.pg_constraint con ON con.conrelid=rel.oid JOIN pg_catalog.pg_namespace as nsp ON nsp.oid=REL.relnamespace AND con.contype=$3 WHERE rel.relkind IN ($4,$5,$6, $7) AND rel.relname = $8 AND nsp.nspname=$9 )::oid[]) | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 0.291138 | 0.086993 | 0.204145 | 0.145569 | 0.058575999999999996 | 4 | 46 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8891863587933273823 | SELECT * FROM "tbl001EC6050B5D_51" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1610 | 45.610261999999956 | 0.0059819999999999995 | 2.135978 | 0.028329355279503116 | 0.08427167520695682 | 1609 | 4049 | 9 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1912963454269304371 | LOCK TABLE public."tbl001EC6050F3C_18" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.020224 | 0.020224 | 0.020224 | 0.020224 | 0 | 0 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5601425196814916798 | SELECT * FROM "tbl001EC6053093_54" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29288 | 1222.9311689999952 | 0.021225 | 3.9124140000000005 | 0.04175536632750615 | 0.056864613243442524 | 29288 | 117119 | 33 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1083959216749029324 | SELECT * FROM "tbl001EC6053075_60" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 1602 | 33.899819 | 0.010816 | 0.30337000000000003 | 0.021160935705368283 | 0.016400039627368638 | 1601 | 3994 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3556529206787501542 | SELECT l.oid, (SELECT rolname FROM pg_catalog.pg_roles WHERE oid = l.lomowner) AS rolname, (SELECT pg_catalog.array_agg(acl ORDER BY row_n) FROM (SELECT acl, row_n FROM pg_catalog.unnest(coalesce(l.lomacl,pg_catalog.acldefault($1,l.lomowner))) WITH ORDINALITY AS perm(acl,row_n) WHERE NOT EXISTS ( SELECT $2 FROM pg_catalog.unnest(coalesce(pip.initprivs,pg_catalog.acldefault($3,l.lomowner))) AS init(init_acl) WHERE acl = init_acl)) as foo) AS lomacl, (SELECT pg_catalog.array_agg(acl ORDER BY row_n) FROM (SELECT acl, row_n FROM pg_catalog.unnest(coalesce(pip.initprivs,pg_catalog.acldefault($4,l.lomowner))) WITH ORDINALITY AS initp(acl,row_n) WHERE NOT EXISTS ( SELECT $5 FROM pg_catalog.unnest(coalesce(l.lomacl,pg_catalog.acldefault($6,l.lomowner))) AS permp(orig_acl) WHERE acl = orig_acl)) as foo) AS rlomacl, $7 AS initlomacl, $8 AS initrlomacl FROM pg_largeobject_metadata l LEFT JOIN pg_init_privs pip ON (l.oid = pip.objoid AND pip.classoid = $9::regclass AND pip.objsubid = $10) | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.09134300000000001 | 0.008333 | 0.010189 | 0.009134300000000001 | 0.0006154156400352527 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2190513480015438458 | SELECT * FROM "tbl001EC6056300_10" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29330 | 1760.3829979999987 | 0.032705 | 12.777135 | 0.06001987719058991 | 0.09707651464932486 | 29330 | 117286 | 34 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -9146034279553306384 | SELECT last_value, is_called FROM public.dl_meter_device_data_id_seq | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 6.512602000000001 | 0.578026 | 0.7523610000000001 | 0.6512602000000001 | 0.059181437182278716 | 10 | 0 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2631945879788793805 | INSERT INTO "tbl001EC6050E4D_81" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 5023 | 582.7742710000001 | 0.019018999999999998 | 4.121541000000001 | 0.11602115687835969 | 0.24591832374257447 | 5023 | 32019 | 476 | 7115 | 211 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 15083 | 6489 | 29973932 |
| 16385 | 16384 | t | -10637612914751176 | SELECT pg_database_size($1) | 0 | 0 | 0 | 0 | 0 | 0 | 708710 | 3436389.9257983947 | 0.597112 | 191.038768 | 4.84879559452797 | 5.012386531904744 | 708710 | 2480486 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1663206667411303115 | INSERT INTO "tbl001EC6052F1E_9" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 15068 | 1040.2443230000003 | 0.018701 | 7.360646999999999 | 0.0690366553623576 | 0.14458181193909583 | 15068 | 94774 | 289 | 10634 | 1461 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 45246 | 7962 | 44996156 |
| 16385 | 16384 | t | 5877624454313594148 | SELECT a.attnum, a.attname, a.atttypmod, a.attstattarget, a.attstorage, t.typstorage, a.attnotnull, a.atthasdef, a.attisdropped, a.attlen, a.attalign, a.attislocal, pg_catalog.format_type(t.oid, a.atttypmod) AS atttypname, array_to_string(a.attoptions, $1) AS attoptions, CASE WHEN a.attcollation <> t.typcollation THEN a.attcollation ELSE $2 END AS attcollation, a.attcompression AS attcompression, pg_catalog.array_to_string(ARRAY(SELECT pg_catalog.quote_ident(option_name) || $3 || pg_catalog.quote_literal(option_value) FROM pg_catalog.pg_options_to_table(attfdwoptions) ORDER BY option_name), $4) AS attfdwoptions, a.attidentity, CASE WHEN a.atthasmissing AND NOT a.attisdropped THEN a.attmissingval ELSE $5 END AS attmissingval, a.attgenerated FROM pg_catalog.pg_attribute a LEFT JOIN pg_catalog.pg_type t ON a.atttypid = t.oid WHERE a.attrelid = $6::pg_catalog.oid AND a.attnum > $7::pg_catalog.int2 ORDER BY a.attnum | 0 | 0 | 0 | 0 | 0 | 0 | 1959 | 907.9811759999976 | 0.042429 | 9.696138999999999 | 0.46349217764165435 | 0.6658181930265474 | 87416 | 85874 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8964275897284179474 | INSERT INTO "tbl001EC6050D30_3" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 8962 | 376.8362409999996 | 0.016143 | 5.651797 | 0.04204823041731741 | 0.10558114344929502 | 8962 | 54933 | 27 | 2577 | 675 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 26911 | 1825 | 14132343 |
| 16385 | 16384 | t | 6205127235980390441 | LOCK TABLE public."tbl001EC6056D48_55" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.300713 | 0.020159 | 0.044731 | 0.0300713 | 0.006494145071524042 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | -8046268409171700158 | CREATE TABLE _d77af18ac3c1ce7e583ede0a8f904197(cmd_output text) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 7.7319 | 7.7319 | 7.7319 | 7.7319 | 0 | 0 | 501 | 5 | 24 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 92 | 25 | 118709 |
| 16385 | 16384 | t | -7149998903834283460 | CREATE TABLE IF NOT EXISTS "tbl001EC6050B87_7" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Operating_State_I_Status_1" DOUBLE PRECISION DEFAULT NULL, "Vendor_Operating_State_I_Status_Vendor_2" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_1_bits_0_31_3" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_2_bits_32_63_4" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8" DOUBLE PRECISION DEFAULT NULL, "AC_Total_Current_I_AC_Current_A_9" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_A_Current_I_AC_CurrentA_A_10" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_B_Current_I_AC_CurrentB_A_11" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_C_Current_I_AC_CurrentC_A_12" DOUBLE PRECISION DEFAULT NULL, "ac_current_Scale_Factor_I_AC_Current_SF_13" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19" DOUBLE PRECISION DEFAULT NULL, "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20" DOUBLE PRECISION DEFAULT NULL, "AC_Power_I_AC_Power_W_21" DOUBLE PRECISION DEFAULT NULL, "ac_power_Scale_Factor_I_AC_Power_SF_22" DOUBLE PRECISION DEFAULT NULL, "AC_Frequency_I_AC_Frequency_Hz_23" DOUBLE PRECISION DEFAULT NULL, "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24" DOUBLE PRECISION DEFAULT NULL, "Apparent_Power_I_AC_VA_VA_25" DOUBLE PRECISION DEFAULT NULL, "apparent_power_Scale_Factor_I_AC_VA_SF_26" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_I_AC_VAR_Var_27" DOUBLE PRECISION DEFAULT NULL, "reactive_power_Scale_Factor_I_AC_VAR_28" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_I_AC_PF_29" DOUBLE PRECISION DEFAULT NULL, "power_factor_Scale_Factor_I_AC_PF_SF_30" DOUBLE PRECISION DEFAULT NULL, "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31" DOUBLE PRECISION DEFAULT NULL, "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32" DOUBLE PRECISION DEFAULT NULL, "DC_Current_I_DC_Current_A_33" DOUBLE PRECISION DEFAULT NULL, "dc_current_Scale_Factor_I_DC_Current_SF_34" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_I_DC_Voltage_V_35" DOUBLE PRECISION DEFAULT NULL, "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36" DOUBLE PRECISION DEFAULT NULL, "DC_Power_I_DC_Power_W_37" DOUBLE PRECISION DEFAULT NULL, "dc_power_Scale_Factor_I_DC_Power_SF_38" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_I_Temp_Cab_Deg_C_39" DOUBLE PRECISION DEFAULT NULL, "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_I_Temp_Trans_Deg_C_41" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_I_Temp_Other_Deg_C_42" DOUBLE PRECISION DEFAULT NULL, "temperature_Scale_Factor_I_Temp_SF_43" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_ID_44" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_Model_Block_45" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_46" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_1_47" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_2_48" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_3_49" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_4_50" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_5_51" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_6_52" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_7_53" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_8_54" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_1_55" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_2_56" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_3_57" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_4_58" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_5_59" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_6_60" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_7_61" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_8_62" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_1_63" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_2_64" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_3_65" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_4_66" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_1_67" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_2_68" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_3_69" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_4_70" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_1_71" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_2_72" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_3_73" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_4_74" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_5_75" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_6_76" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_7_77" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_8_78" DOUBLE PRECISION DEFAULT NULL, "C_DeviceAddress_Modbus_ID_79" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_End_Block_matches_FFFF_80" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_Last_Block_matches_0_81" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.392176 | 6.392176 | 6.392176 | 6.392176 | 0 | 0 | 1187 | 4 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 281 | 4 | 44791 |
| 16385 | 16384 | t | -1762758732810530806 | SELECT * FROM "tbl001EC60537AE_1" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.19921699999999998 | 0.19921699999999998 | 0.19921699999999998 | 0.19921699999999998 | 0 | 100 | 3 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4562635154046073478 | LOCK TABLE public."tbl001EC6050F42_2" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.018768 | 0.018768 | 0.018768 | 0.018768 | 0 | 0 | 6 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1328844990116483517 | SELECT * FROM "tbl001EC6050F3C_17" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 140 | 5.776682000000001 | 0.01821 | 1.281835 | 0.04126201428571429 | 0.1067455178722464 | 139 | 277 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1353058424408335585 | LOCK TABLE public."tbl001EC6050B87_7" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 0.23829500000000003 | 0.017191 | 0.044906 | 0.026477222222222225 | 0.010442926811725808 | 0 | 54 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3196603689379148377 | SELECT * FROM pg_stat_database_conflicts | 0 | 0 | 0 | 0 | 0 | 0 | 178818 | 1099449.395818005 | 0.065527 | 207.385693 | 6.14842686876034 | 5.744199445032708 | 715272 | 178818 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7259059839401016012 | SELECT * FROM "tbl001EC6050F3A_1" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 21 | 37.187565000000006 | 0.15940400000000002 | 9.057572 | 1.7708364285714289 | 2.384123556747418 | 2100 | 274 | 22 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2570909912959527909 | COPY public."tbl001EC6050B5D_3" ("time", error, lowrange, highrange, "DC_Voltage_V_1", "Apparent_AC_Power_VA_2", "AC_Grid_Frequency_Hz_3", "AC_Power_Stage_Current_A_4", "L1_to_L2_AC_Voltage_V_5", "L2_to_L3_AC_Voltage_V_6", "L1_to_L3_AC_Voltage_V_7", "Phase_Sequence_8", "AC_Energy_kWh_9", "On_Grid_Hours_Hrs_10", "Fan_On_Time_Hours_Hrs_11", "AC_Contactors_Cycles_12", "Network_ID_13", "Informative_Alarms_14", "Inverter_AC_Output_Current_A_15", "Critical_Alarms_16") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 6.621848 | 0.034782 | 1.83918 | 0.7357608888888889 | 0.5856831925952316 | 3548 | 27 | 4 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -7129965142229186101 | SELECT datid ,datname ,numbackends ,xact_commit ,xact_rollback ,blks_read ,blks_hit ,tup_returned ,tup_fetched ,tup_inserted ,tup_updated ,tup_deleted ,conflicts ,temp_files ,temp_bytes ,deadlocks ,blk_read_time ,blk_write_time ,stats_reset FROM pg_stat_database | 0 | 0 | 0 | 0 | 0 | 0 | 58487 | 280184.3421260012 | 0.165216 | 106.864029 | 4.790540498332983 | 5.739480944678354 | 292435 | 58487 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5357413121830611143 | SELECT * FROM "tbl001EC6050E0D_1" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 4.750085 | 0.16267 | 1.839876 | 0.4750085000000001 | 0.5100363405704048 | 1000 | 113 | 4 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5299266603066551248 | SELECT * FROM "tbl001EC6050B87_1" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 12696 | 446.7768719999996 | 0.01472 | 1.8908289999999999 | 0.035190364839319595 | 0.027633772422189423 | 12695 | 37273 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8951947008961658025 | SELECT * FROM "tbl001EC6050B08_51" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 2092 | 109.49667599999997 | 0.020151000000000002 | 19.379048 | 0.052340667304015195 | 0.4465781829161353 | 2092 | 6240 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 9117855755238782286 | SELECT * FROM "tbl001EC6050B42_52" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 15.756939 | 0.505538 | 4.148168 | 2.2509912857142855 | 1.4595460487106173 | 700 | 73 | 16 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 8347632181829244141 | INSERT INTO "tbl001EC6053113_51" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 15042 | 1011.9155679999967 | 0.01865 | 4.190401 | 0.0672726743784067 | 0.12634566758937857 | 15042 | 94531 | 321 | 10569 | 1426 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 45168 | 7902 | 44534144 |
| 16385 | 16384 | t | 6208962007635167111 | CREATE TABLE IF NOT EXISTS "tbl001EC6053CD9_5" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Energy_Consumption_kWh_1" DOUBLE PRECISION DEFAULT NULL, "Real_Power_kW_2" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 4.722887 | 4.722887 | 4.722887 | 4.722887 | 0 | 0 | 415 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 105 | 1 | 11064 |
| 16385 | 16384 | t | 3228175474821286670 | LOCK TABLE public."tbl001EC6050B5D_3" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 0.29401900000000003 | 0.024166 | 0.049192 | 0.032668777777777776 | 0.007118824400103306 | 0 | 54 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3855621884648895582 | SELECT * FROM "tbl001EC6056D47_52" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 3.4817080000000002 | 0.929502 | 1.2934050000000001 | 1.1605693333333333 | 0.1639988691105995 | 300 | 154 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -3008799328338101810 | LOCK TABLE public."tbl001EC6050F3A_2" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.301406 | 0.017504 | 0.058717 | 0.0301406 | 0.012978449038309624 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8952720130018122930 | INSERT INTO "tbl001EC6053093_55" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 15068 | 843.4276610000029 | 0.020566 | 3.7326859999999997 | 0.05597475849482326 | 0.07897568964691613 | 15068 | 96140 | 36 | 10250 | 1617 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 45246 | 7642 | 42720410 |
| 16385 | 16384 | t | -802287773578263999 | SELECT * FROM "tbl001EC6056D48_55" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29194 | 1166.0303689999985 | 0.02196 | 6.034558 | 0.03994075388778504 | 0.047862999024581944 | 29194 | 87576 | 6 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4960955850395131556 | CREATE TABLE IF NOT EXISTS "tbl001EC6050BAC_6" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "DC_Voltage_V_1" DOUBLE PRECISION DEFAULT NULL, "Apparent_AC_Power_VA_2" DOUBLE PRECISION DEFAULT NULL, "AC_Grid_Frequency_Hz_3" DOUBLE PRECISION DEFAULT NULL, "AC_Power_Stage_Current_A_4" DOUBLE PRECISION DEFAULT NULL, "L1_to_L2_AC_Voltage_V_5" DOUBLE PRECISION DEFAULT NULL, "L2_to_L3_AC_Voltage_V_6" DOUBLE PRECISION DEFAULT NULL, "L1_to_L3_AC_Voltage_V_7" DOUBLE PRECISION DEFAULT NULL, "Phase_Sequence_8" DOUBLE PRECISION DEFAULT NULL, "AC_Energy_kWh_9" DOUBLE PRECISION DEFAULT NULL, "On_Grid_Hours_Hrs_10" DOUBLE PRECISION DEFAULT NULL, "Fan_On_Time_Hours_Hrs_11" DOUBLE PRECISION DEFAULT NULL, "AC_Contactors_Cycles_12" DOUBLE PRECISION DEFAULT NULL, "Network_ID_13" DOUBLE PRECISION DEFAULT NULL, "Informative_Alarms_14" DOUBLE PRECISION DEFAULT NULL, "Inverter_AC_Output_Current_A_15" DOUBLE PRECISION DEFAULT NULL, "Critical_Alarms_16" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 5.449209 | 5.449209 | 5.449209 | 5.449209 | 0 | 0 | 537 | 1 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 136 | 2 | 15263 |
| 16385 | 16384 | t | 3696515394032386122 | CREATE TABLE IF NOT EXISTS "tbl001EC6050F3C_4" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Operating_State_I_Status_1" DOUBLE PRECISION DEFAULT NULL, "Vendor_Operating_State_I_Status_Vendor_2" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_1_bits_0_31_3" DOUBLE PRECISION DEFAULT NULL, "Event_Flags_I_Event_2_bits_32_63_4" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7" DOUBLE PRECISION DEFAULT NULL, "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8" DOUBLE PRECISION DEFAULT NULL, "AC_Total_Current_I_AC_Current_A_9" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_A_Current_I_AC_CurrentA_A_10" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_B_Current_I_AC_CurrentB_A_11" DOUBLE PRECISION DEFAULT NULL, "AC_Phase_C_Current_I_AC_CurrentC_A_12" DOUBLE PRECISION DEFAULT NULL, "ac_current_Scale_Factor_I_AC_Current_SF_13" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18" DOUBLE PRECISION DEFAULT NULL, "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19" DOUBLE PRECISION DEFAULT NULL, "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20" DOUBLE PRECISION DEFAULT NULL, "AC_Power_I_AC_Power_W_21" DOUBLE PRECISION DEFAULT NULL, "ac_power_Scale_Factor_I_AC_Power_SF_22" DOUBLE PRECISION DEFAULT NULL, "AC_Frequency_I_AC_Frequency_Hz_23" DOUBLE PRECISION DEFAULT NULL, "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24" DOUBLE PRECISION DEFAULT NULL, "Apparent_Power_I_AC_VA_VA_25" DOUBLE PRECISION DEFAULT NULL, "apparent_power_Scale_Factor_I_AC_VA_SF_26" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_I_AC_VAR_Var_27" DOUBLE PRECISION DEFAULT NULL, "reactive_power_Scale_Factor_I_AC_VAR_28" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_I_AC_PF_29" DOUBLE PRECISION DEFAULT NULL, "power_factor_Scale_Factor_I_AC_PF_SF_30" DOUBLE PRECISION DEFAULT NULL, "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31" DOUBLE PRECISION DEFAULT NULL, "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32" DOUBLE PRECISION DEFAULT NULL, "DC_Current_I_DC_Current_A_33" DOUBLE PRECISION DEFAULT NULL, "dc_current_Scale_Factor_I_DC_Current_SF_34" DOUBLE PRECISION DEFAULT NULL, "DC_Voltage_I_DC_Voltage_V_35" DOUBLE PRECISION DEFAULT NULL, "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36" DOUBLE PRECISION DEFAULT NULL, "DC_Power_I_DC_Power_W_37" DOUBLE PRECISION DEFAULT NULL, "dc_power_Scale_Factor_I_DC_Power_SF_38" DOUBLE PRECISION DEFAULT NULL, "Cabinet_Temperature_I_Temp_Cab_Deg_C_39" DOUBLE PRECISION DEFAULT NULL, "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40" DOUBLE PRECISION DEFAULT NULL, "Transformer_Temperature_I_Temp_Trans_Deg_C_41" DOUBLE PRECISION DEFAULT NULL, "Other_Temperature_I_Temp_Other_Deg_C_42" DOUBLE PRECISION DEFAULT NULL, "temperature_Scale_Factor_I_Temp_SF_43" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_ID_44" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_Model_Block_45" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_46" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_1_47" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_2_48" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_3_49" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_4_50" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_5_51" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_6_52" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_7_53" DOUBLE PRECISION DEFAULT NULL, "Manufacturer_C_Manufacturer_string_part_8_54" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_1_55" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_2_56" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_3_57" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_4_58" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_5_59" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_6_60" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_7_61" DOUBLE PRECISION DEFAULT NULL, "Inverter_Type_C_Model_string_part_8_62" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_1_63" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_2_64" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_3_65" DOUBLE PRECISION DEFAULT NULL, "C_Options_Manufacturer_specific_string_part_4_66" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_1_67" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_2_68" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_3_69" DOUBLE PRECISION DEFAULT NULL, "C_Version_Manufacturer_specific_string_part_4_70" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_1_71" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_2_72" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_3_73" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_4_74" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_5_75" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_6_76" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_7_77" DOUBLE PRECISION DEFAULT NULL, "C_SerialNumber_Manufacturer_specific_string_part_8_78" DOUBLE PRECISION DEFAULT NULL, "C_DeviceAddress_Modbus_ID_79" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_DID_End_Block_matches_FFFF_80" DOUBLE PRECISION DEFAULT NULL, "C_SunSpec_Length_Last_Block_matches_0_81" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 6.85263 | 6.85263 | 6.85263 | 6.85263 | 0 | 0 | 1151 | 1 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 280 | 6 | 61437 |
| 16385 | 16384 | t | -361368321428642523 | COPY public."tbl001EC6050189_32" ("time", error, lowrange, highrange, "Volts_A_N_Volts_1", "Volts_B_N_Volts_2", "Volts_C_N_Volts_3", "Volts_A_B_Volts_4", "Volts_B_C_Volts_5", "Volts_C_A_Volts_6", "Amps_A_Amps_7", "Amps_B_Amps_8", "Amps_C_Amps_9", "Watts_3_Ph_total_kW_10", "VARs_3_Ph_total_kVAR_11", "VAs_3_Ph_total_kVA_12", "Power_Factor_3_Ph_total_13", "Frequency_Hz_14", "Neutral_Current_Amps_15", "W_hours_Received_kWh_16", "W_hours_Delivered_kWh_17", "W_hours_Net_kWh_18", "W_hours_Total_kWh_19", "VAR_hours_Positive_kVARh_20", "VAR_hours_Negative_kVARh_21", "VAR_hours_Net_kVARh_22", "VAR_hours_Total_kVARh_23", "VA_hours_Total_kVAh_24", "Amps_A_Average_Amps_25", "Amps_B_Average_Amps_26", "Amps_C_Average_Amps_27", "Positive_Watts_3_Ph_Average_kW_28", "Positive_VARs_3_Ph_Average_kVAR_29", "Negative_Watts_3_Ph_Average_kW_30", "Negative_VARs_3_Ph_Average_kVAR_31", "VAs_3_Ph_Average_kVA_32", "Positive_PF_3_Ph_Average_33", "Negative_PF_3_Ph_Average_34", "Volts_A_N_Min_Volts_35", "Volts_B_N_Min_Volts_36", "Volts_C_N_Min_Volts_37", "Volts_A_B_Min_Volts_38", "Volts_B_C_Min_Volts_39", "Volts_C_A_Min_Volts_40", "Amps_A_Min_Avg_Demand_Amps_41", "Amps_B_Min_Avg_Demand_Amps_42", "Amps_C_Min_Avg_Demand_Amps_43", "Positive_Watts_3_Ph_Min_Avg_Demand_kW_44", "Positive_VARs_3_Ph_Min_Avg_Demand_kVAR_45", "Negative_Watts_3_Ph_Min_Avg_Demand_kW_46", "Negative_VARs_3_Ph_Min_Avg_Demand_kVAR_47", "VAs_3_Ph_Min_Avg_Demand_kVA_48", "Positive_PF_3_Ph_Min_Avg_Demand_49", "Negative_PF_3_Ph_Min_Avg_Demand_50", "Frequency_Min_Hz_51", "Volts_A_N_Max_Volts_52", "Volts_B_N_Max_Volts_53", "Volts_C_N_Max_Volts_54", "Volts_A_B_Max_Volts_55", "Volts_B_C_Max_Volts_56", "Volts_C_A_Max_Volts_57", "Amps_A_Max_Avg_Demand_Amps_58", "Amps_B_Max_Avg_Demand_Amps_59", "Amps_C_Max_Avg_Demand_Amps_60", "Positive_Watts_3_Ph_Max_Avg_Demand_kW_61", "Positive_VARs_3_Ph_Max_Avg_Demand_kVAR_62", "Negative_Watts_3_Ph_Max_Avg_Demand_kW_63", "Negative_VARs_3_Ph_Max_Avg_Demand_kVAR_64", "VAs_3_Ph_Max_Avg_Demand_kVA_65", "Positive_PF_3_Ph_Max_Avg_Demand_66", "Negative_PF_3_Ph_Max_Avg_Demand_67", "Frequency_Max_Hz_68", "Volts_A_N_THD_69", "Volts_B_N_THD_70", "Volts_C_N_THD_71", "Amps_A_THD_72", "Amps_B_THD_73", "Amps_C_THD_74", "Phase_A_Current_0th_harmonic_magnitude_75", "Phase_A_Current_1st_harmonic_magnitude_76", "Phase_A_Current_2nd_harmonic_magnitude_77", "Phase_A_Current_3rd_harmonic_magnitude_78", "Phase_A_Current_4th_harmonic_magnitude_79", "Phase_A_Current_5th_harmonic_magnitude_80", "Phase_A_Current_6th_harmonic_magnitude_81", "Phase_A_Current_7th_harmonic_magnitude_82", "Phase_A_Voltage_0th_harmonic_magnitude_83", "Phase_A_Voltage_1st_harmonic_magnitude_84", "Phase_A_Voltage_2nd_harmonic_magnitude_85", "Phase_A_Voltage_3rd_harmonic_magnitude_86", "Phase_B_Current_0th_harmonic_magnitude_87", "Phase_B_Current_1st_harmonic_magnitude_88", "Phase_B_Current_2nd_harmonic_magnitude_89", "Phase_B_Current_3rd_harmonic_magnitude_90", "Phase_B_Current_4th_harmonic_magnitude_91", "Phase_B_Current_5th_harmonic_magnitude_92", "Phase_B_Current_6th_harmonic_magnitude_93", "Phase_B_Current_7th_harmonic_magnitude_94", "Phase_B_Voltage_0th_harmonic_magnitude_95", "Phase_B_Voltage_1st_harmonic_magnitude_96", "Phase_B_Voltage_2nd_harmonic_magnitude_97", "Phase_B_Voltage_3rd_harmonic_magnitude_98", "Phase_C_Current_0th_harmonic_magnitude_99", "Phase_C_Current_1st_harmonic_magnitude_100", "Phase_C_Current_2nd_harmonic_magnitude_101", "Phase_C_Current_3rd_harmonic_magnitude_102", "Phase_C_Current_4th_harmonic_magnitude_103", "Phase_C_Current_5th_harmonic_magnitude_104", "Phase_C_Current_6th_harmonic_magnitude_105", "Phase_C_Current_7th_harmonic_magnitude_106", "Phase_C_Voltage_0th_harmonic_magnitude_107", "Phase_C_Voltage_1st_harmonic_magnitude_108", "Phase_C_Voltage_2nd_harmonic_magnitude_109", "Phase_C_Voltage_3rd_harmonic_magnitude_110", "Angle_Phase_A_Current_Degrees_111", "Angle_Phase_B_Current_Degrees_112", "Angle_Phase_C_Current_Degrees_113", "Angle_Volts_A_B_Degrees_114", "Angle_Volts_B_C_Degrees_115", "Angle_Volts_C_A_Degrees_116") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 100.114579 | 0.429781 | 21.651467 | 11.123842111111111 | 6.975856546487519 | 3561 | 281 | 225 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -155908022337956364 | SELECT * FROM "tbl001EC6056FD2_51" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 0.595137 | 0.16927899999999999 | 0.425858 | 0.2975685 | 0.12828950000000003 | 200 | 118 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4199849316459484872 | DISCARD ALL | 0 | 0 | 0 | 0 | 0 | 0 | 3613364 | 94724.99498500764 | 0.008329 | 149.909952 | 0.026215182025668762 | 0.1672626975463534 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8652130620705086090 | LOCK TABLE public."tbl001EC6050F3A_3" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 1.467808 | 0.019546 | 1.228498 | 0.14678080000000004 | 0.36067644840460544 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -651826919375886170 | INSERT INTO "tbl001EC6050B87_3" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24,$25,$26,$27,$28,$29,$30,$31,$32,$33,$34,$35,$36,$37,$38,$39,$40,$41,$42,$43,$44,$45,$46,$47,$48,$49,$50,$51,$52,$53,$54,$55,$56,$57,$58,$59,$60,$61,$62,$63,$64,$65,$66,$67,$68,$69,$70,$71,$72,$73,$74,$75,$76,$77,$78,$79,$80,$81,$82,$83,$84,$85) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 6394 | 432.05229000000026 | 0.023095 | 2.350257 | 0.06757151861119833 | 0.1246420390524834 | 6394 | 40075 | 205 | 7131 | 589 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 19201 | 6019 | 29936025 |
| 16385 | 16384 | t | 3360188281562576558 | SELECT * FROM "tbl001EC6050D21_80" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 2.6989080000000003 | 0.717149 | 1.249019 | 0.899636 | 0.24713306852382186 | 300 | 72 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -8135777336684366393 | SELECT * FROM "tbl001EC6053019_53" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 3.927219 | 0.022713 | 0.570368 | 0.4363576666666667 | 0.15646901718160622 | 803 | 150 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -1698795857077071261 | SELECT * FROM "tbl001EC6050E4D_81" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 3 | 4.358727 | 0.67696 | 2.172027 | 1.452909 | 0.6116800119577773 | 300 | 140 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5398647473872158721 | SELECT * FROM "tbl001EC605311A_1" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 5936 | 147.15378 | 0.011367 | 2.1968199999999998 | 0.024790057277628102 | 0.04367155741113084 | 5936 | 17800 | 8 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3772327304764377348 | SELECT t.tgname, t.tgfoid::pg_catalog.regproc AS tgfname, pg_catalog.pg_get_triggerdef(t.oid, $1) AS tgdef, t.tgenabled, t.tableoid, t.oid, t.tgisinternal FROM pg_catalog.pg_trigger t LEFT JOIN pg_catalog.pg_trigger u ON u.oid = t.tgparentid WHERE t.tgrelid = $2::pg_catalog.oid AND (NOT t.tgisinternal OR t.tgenabled != u.tgenabled) | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 8.185785 | 0.663986 | 1.259842 | 0.8185785 | 0.20223632998660254 | 10 | 120 | 10 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -278428233097029137 | SELECT * FROM "tbl001EC6056300_50" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29330 | 859.6660340000045 | 0.015662 | 46.635176 | 0.029310127309921604 | 0.277169899403244 | 29330 | 117285 | 35 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 8577855113613826634 | LOCK TABLE public.dl_inverter_device_data IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.40558700000000003 | 0.023691 | 0.085856 | 0.0405587 | 0.02268313245144947 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -5899020838019676558 | LOCK TABLE public."tbl001EC6056D41_9" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 0.259006 | 0.018299 | 0.062009 | 0.0259006 | 0.012331847308493567 | 0 | 60 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 2278296749139447712 | CREATE TABLE IF NOT EXISTS "tbl001EC6053019_53" ( time TIMESTAMP NOT NULL DEFAULT CURRENT_TIMESTAMP, error INTEGER DEFAULT 0, lowrange BIGINT DEFAULT 0, highrange BIGINT DEFAULT 0, "Volts_AB_Volts_1" DOUBLE PRECISION DEFAULT NULL, "Volts_BC_Volts_2" DOUBLE PRECISION DEFAULT NULL, "Volts_CA_Volts_3" DOUBLE PRECISION DEFAULT NULL, "Volts_LL_Average_Volts_4" DOUBLE PRECISION DEFAULT NULL, "Volts_A_Volts_5" DOUBLE PRECISION DEFAULT NULL, "Volts_B_Volts_6" DOUBLE PRECISION DEFAULT NULL, "Volts_C_Volts_7" DOUBLE PRECISION DEFAULT NULL, "Volts_LN_Average_Volts_8" DOUBLE PRECISION DEFAULT NULL, "Amps_A_Amps_9" DOUBLE PRECISION DEFAULT NULL, "Amps_B_Amps_10" DOUBLE PRECISION DEFAULT NULL, "Amps_C_Amps_11" DOUBLE PRECISION DEFAULT NULL, "Frequency_Hz_12" DOUBLE PRECISION DEFAULT NULL, "KW_A_kW_13" DOUBLE PRECISION DEFAULT NULL, "KW_B_kW_14" DOUBLE PRECISION DEFAULT NULL, "KW_C_KW_15" DOUBLE PRECISION DEFAULT NULL, "PF_Sign_A_PF_16" DOUBLE PRECISION DEFAULT NULL, "PF_Sign_B_PF_17" DOUBLE PRECISION DEFAULT NULL, "PF_Sign_C_PF_18" DOUBLE PRECISION DEFAULT NULL, "Volt_Unbalance_19" DOUBLE PRECISION DEFAULT NULL, "Current_Unbalance_20" DOUBLE PRECISION DEFAULT NULL, "Delivered_Energy_kWh_21" DOUBLE PRECISION DEFAULT NULL, "Received_Energy_kWh_22" DOUBLE PRECISION DEFAULT NULL, "Real_Power_kW_23" DOUBLE PRECISION DEFAULT NULL, "Power_Factor_PF_24" DOUBLE PRECISION DEFAULT NULL, "Reactive_Power_kVAR_25" DOUBLE PRECISION DEFAULT NULL, PRIMARY KEY (time) ) | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 10.141104 | 10.141104 | 10.141104 | 10.141104 | 0 | 0 | 926 | 2 | 51 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 172 | 47 | 253436 |
| 16385 | 16384 | t | -6046448516502485600 | INSERT INTO "tbl001EC6050BAC_51" VALUES ($1,$2,$3,$4,$5,$6,$7,$8,$9,$10,$11,$12,$13,$14,$15,$16,$17,$18,$19,$20,$21,$22,$23,$24) ON CONFLICT (time) DO NOTHING | 0 | 0 | 0 | 0 | 0 | 0 | 9626 | 523.5836179999993 | 0.017786 | 15.827875000000002 | 0.054392646789943905 | 0.23186806055745618 | 9626 | 58693 | 113 | 5559 | 317 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 28905 | 5157 | 24364459 |
| 16385 | 16384 | t | 7912770291323265081 | SELECT * FROM "tbl001EC6050B08_2" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 9 | 14.705986 | 1.0991 | 2.914765 | 1.6339984444444446 | 0.5740833455193517 | 900 | 147 | 0 | 47 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2162775994501661309 | SELECT * FROM "tbl001EC6056D47_9" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 2 | 3.482795 | 1.5892009999999999 | 1.893594 | 1.7413975 | 0.15219650000000007 | 200 | 116 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 7682482127983211317 | COPY public."tbl001EC6050F3C_13" ("time", error, lowrange, highrange, "Operating_State_I_Status_1", "Vendor_Operating_State_I_Status_Vendor_2", "Event_Flags_I_Event_1_bits_0_31_3", "Event_Flags_I_Event_2_bits_32_63_4", "Vendor_Event_Flags_I_Event_1_Vendor_bits_0_31_5", "Vendor_Event_Flags_I_Event_2_Vendor_bits_32_63_6", "Vendor_Event_Flags_I_Event_3_Vendor_bits_64_95_7", "Vendor_Event_Flags_I_Event_4_Vendor_bits_96_127_8", "AC_Total_Current_I_AC_Current_A_9", "AC_Phase_A_Current_I_AC_CurrentA_A_10", "AC_Phase_B_Current_I_AC_CurrentB_A_11", "AC_Phase_C_Current_I_AC_CurrentC_A_12", "ac_current_Scale_Factor_I_AC_Current_SF_13", "AC_Voltage_Phase_AB_I_AC_VoltageAB_V_14", "AC_Voltage_Phase_BC_I_AC_VoltageBC_V_15", "AC_Voltage_Phase_CA_I_AC_VoltageCA_V_16", "AC_Voltage_Phase_A_to_neutral_I_AC_VoltageAN_V_17", "AC_Voltage_Phase_B_to_neutral_I_AC_VoltageBN_V_18", "AC_Voltage_Phase_C_to_neutral_I_AC_VoltageCN_V_19", "ac_voltage_Scale_Factor_I_AC_Voltage_SF_20", "AC_Power_I_AC_Power_W_21", "ac_power_Scale_Factor_I_AC_Power_SF_22", "AC_Frequency_I_AC_Frequency_Hz_23", "ac_frequency_Scale_Factor_I_AC_Frequency_SF_24", "Apparent_Power_I_AC_VA_VA_25", "apparent_power_Scale_Factor_I_AC_VA_SF_26", "Reactive_Power_I_AC_VAR_Var_27", "reactive_power_Scale_Factor_I_AC_VAR_28", "Power_Factor_I_AC_PF_29", "power_factor_Scale_Factor_I_AC_PF_SF_30", "AC_Lifetime_Energy_I_AC_Energy_WH_Wh_31", "ac_lifetime_energy_Scale_Factor_I_AC_Energy_WH_SF_32", "DC_Current_I_DC_Current_A_33", "dc_current_Scale_Factor_I_DC_Current_SF_34", "DC_Voltage_I_DC_Voltage_V_35", "dc_voltage_Scale_Factor_I_DC_Voltage_SF_36", "DC_Power_I_DC_Power_W_37", "dc_power_Scale_Factor_I_DC_Power_SF_38", "Cabinet_Temperature_I_Temp_Cab_Deg_C_39", "Coolant_or_Heat_Sink_Temp_I_Temp_Sink_Deg_C_40", "Transformer_Temperature_I_Temp_Trans_Deg_C_41", "Other_Temperature_I_Temp_Other_Deg_C_42", "temperature_Scale_Factor_I_Temp_SF_43", "C_SunSpec_ID_44", "C_SunSpec_DID_Model_Block_45", "C_SunSpec_Length_46", "Manufacturer_C_Manufacturer_string_part_1_47", "Manufacturer_C_Manufacturer_string_part_2_48", "Manufacturer_C_Manufacturer_string_part_3_49", "Manufacturer_C_Manufacturer_string_part_4_50", "Manufacturer_C_Manufacturer_string_part_5_51", "Manufacturer_C_Manufacturer_string_part_6_52", "Manufacturer_C_Manufacturer_string_part_7_53", "Manufacturer_C_Manufacturer_string_part_8_54", "Inverter_Type_C_Model_string_part_1_55", "Inverter_Type_C_Model_string_part_2_56", "Inverter_Type_C_Model_string_part_3_57", "Inverter_Type_C_Model_string_part_4_58", "Inverter_Type_C_Model_string_part_5_59", "Inverter_Type_C_Model_string_part_6_60", "Inverter_Type_C_Model_string_part_7_61", "Inverter_Type_C_Model_string_part_8_62", "C_Options_Manufacturer_specific_string_part_1_63", "C_Options_Manufacturer_specific_string_part_2_64", "C_Options_Manufacturer_specific_string_part_3_65", "C_Options_Manufacturer_specific_string_part_4_66", "C_Version_Manufacturer_specific_string_part_1_67", "C_Version_Manufacturer_specific_string_part_2_68", "C_Version_Manufacturer_specific_string_part_3_69", "C_Version_Manufacturer_specific_string_part_4_70", "C_SerialNumber_Manufacturer_specific_string_part_1_71", "C_SerialNumber_Manufacturer_specific_string_part_2_72", "C_SerialNumber_Manufacturer_specific_string_part_3_73", "C_SerialNumber_Manufacturer_specific_string_part_4_74", "C_SerialNumber_Manufacturer_specific_string_part_5_75", "C_SerialNumber_Manufacturer_specific_string_part_6_76", "C_SerialNumber_Manufacturer_specific_string_part_7_77", "C_SerialNumber_Manufacturer_specific_string_part_8_78", "C_DeviceAddress_Modbus_ID_79", "C_SunSpec_DID_End_Block_matches_FFFF_80", "C_SunSpec_Length_Last_Block_matches_0_81") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.110203 | 0.110203 | 0.110203 | 0.110203 | 0 | 7 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -2909072935829659850 | SELECT * FROM "tbl001EC6050BAC_10" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 19154 | 514.7684809999975 | 0.00594 | 38.007600000000004 | 0.026875246998015977 | 0.2919303550023845 | 19153 | 56652 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4628838447869404653 | LOCK TABLE public."tbl001EC6050D16_51" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.15696300000000002 | 0.017338 | 0.043306 | 0.0261605 | 0.010135634444046082 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 3442726470276445912 | SELECT oid, pg_catalog.format_type(oid, $2) AS typname FROM pg_catalog.pg_type WHERE oid = ANY($1) ORDER BY oid | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.035169 | 0.035169 | 0.035169 | 0.035169 | 0 | 4 | 12 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4543281955003066313 | COPY public."tbl001EC6053109_1" ("time", error, lowrange, highrange, "Net_Energy_kWh_1", "Import_Energy_kWh_2", "Export_Energy_kWh_3", "Real_Power_kW_4", "Reactive_Power_kVAR_5", "Apparent_Power_kVA_6", "Voltage_Average_V_7", "Voltage_L_L_Average_V_8", "Current_Average_A_9", "Total_Power_Factor_10", "Frequency_Hz_11", "Voltage_A_V_12", "Voltage_B_V_13", "Voltage_C_V_14", "Voltage_AB_V_15", "Voltage_BC_V_16", "Votlage_AC_V_17", "Current_A_A_18", "Current_B_A_19", "Current_C_A_20", "Power_Factor_A_21", "Power_Factor_B_22", "Power_Factor_C_23", "Import_Energy_Phase_A_kWh_24", "Import_Energy_Phase_B_kWh_25", "Import_Energy_Phase_C_kWh_26", "Export_Energy_Phase_A_kWh_27", "Export_Energy_Phase_B_kWh_28", "Export_Energy_Phase_C_kWh_29") TO stdout | 0 | 0 | 0 | 0 | 0 | 0 | 10 | 6873.232637 | 386.669322 | 860.127974 | 687.3232636999999 | 118.8634003508935 | 457053 | 2970 | 19051 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | -4755594565471483866 | SELECT * FROM "tbl001EC6056300_50" ORDER BY "time" DESC LIMIT $1 OFFSET $2 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.49635100000000004 | 0.49635100000000004 | 0.49635100000000004 | 0.49635100000000004 | 0 | 100 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 1818291803630412711 | SELECT * FROM "tbl001EC6053093_55" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29288 | 1226.0985259999952 | 0.022779999999999998 | 4.199442 | 0.04186351154056275 | 0.056979428328169324 | 29288 | 117118 | 34 | 2 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 5252035872888520135 | LOCK TABLE public."tbl001EC6050D16_6" IN ACCESS SHARE MODE | 0 | 0 | 0 | 0 | 0 | 0 | 6 | 0.458531 | 0.018262 | 0.34737 | 0.07642183333333334 | 0.12124284568091248 | 0 | 36 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 13761 | t | 6775835418052206827 | DROP TABLE IF EXISTS _de27fadfbf2fd0a1680b9a5f0e1ef373 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 0.886649 | 0.886649 | 0.886649 | 0.886649 | 0 | 0 | 5 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 16385 | 16384 | t | 4343719152629286573 | SELECT * FROM "tbl001EC6056D48_52" ORDER BY time DESC LIMIT $1 | 0 | 0 | 0 | 0 | 0 | 0 | 29194 | 1174.4945929999963 | 0.021846 | 2.4359 | 0.04023068414742755 | 0.03239045824297949 | 29194 | 87576 | 6 | 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |